AI Article Synopsis

Article Abstract

Use of electronic animal identification technologies by livestock managers is increasing, but performance of these technologies can be variable when used in livestock production environments. This study was conducted to determine whether 1) read distance of low-frequency radio frequency identification (RFID) transceivers is affected by type of transponder being interrogated; 2) read distance variation of low-frequency RFID transceivers is affected by transceiver manufacturer; and 3) read distance of various transponder-transceiver manufacturer combinations meet the 2004 United States Animal Identification Plan (USAIP) bovine standards subcommittee minimum read distance recommendation of 60 cm. Twenty-four transceivers (n = 5 transceivers per manufacturer for Allflex, Boontech, Farnam, and Osborne; n = 4 transceivers for Destron Fearing) were tested with 60 transponders [n = 10 transponders per type for Allflex full duplex B (FDX-B), Allflex half duplex (HDX), Destron Fearing FDX-B, Farnam FDX-B, and Y-Tex FDX-B; n = 6 for Temple FDX-B (EM Microelectronic chip); and n = 4 for Temple FDX-B (HiTag chip)] presented in the parallel orientation. All transceivers and transponders met International Organization for Standardization 11784 and 11785 standards. Transponders represented both one-half duplex and full duplex low-frequency air interface technologies. Use of a mechanical trolley device enabled the transponders to be presented to the center of each transceiver at a constant rate, thereby reducing human error. Transponder and transceiver manufacturer interacted (P < 0.0001) to affect read distance, indicating that transceiver performance was greatly dependent upon the transponder type being interrogated. Twenty-eight of 30 combinations of transceivers and transponders evaluated met the minimum recommended USAIP read distance. The mean read distance across all 30 combinations was 45.1 to 129.4 cm. Transceiver manufacturer and transponder type interacted to affect read distance variance (P < 0.05). Maximum read distance performance of low-frequency RFID technologies with low variance can be achieved by selecting specific transponder-transceiver combinations.

Download full-text PDF

Source
http://dx.doi.org/10.2527/jas.2009-2070DOI Listing

Publication Analysis

Top Keywords

read distance
40
transceiver manufacturer
12
read
10
distance
9
distance performance
8
variation low-frequency
8
low-frequency radio
8
radio frequency
8
frequency identification
8
animal identification
8

Similar Publications

Purpose: To evaluate the intermediate-term visual and safety outcomes of the small-incision second-generation implantable miniature telescope (SING IMT) in patients with late-stage age-related macular degeneration (AMD) at 6 months post-surgery.

Design: Retrospective cohort study.

Methods: Medical records of patients implanted with the SING IMT at two sites in Italy were reviewed.

View Article and Find Full Text PDF

Purpose: To evaluate the impact of Implantable Collamer Lens (ICL) implantation on anterior chamber angle parameters and posterior segment structures in highly myopic eyes and explore potential correlations between these changes. The study aimed to assess alterations in superficial and deep vessel density (SVD, DVD), foveal avascular zone (FAZ) area, and retinal nerve fiber layer (RNFL) thickness to clarify the safety profile of ICL implantation.

Methods: Prospective observational study, included 36 highly myopic eyes undergoing ICL implantation in surgery group and 23 non-surgical control eyes in non-surgery group.

View Article and Find Full Text PDF

Improvement of stereopsis following strabismus surgery in adults: a retrospective analysis.

Can J Ophthalmol

January 2025

Department of Ophthalmology, Sheba Medical Center of Israel, Israel; Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.

Objective: Adults who undergo strabismus surgery, in addition to cosmesis, could benefit from improved stereopsis. This improvement is associated with the performance of motor skill tasks in young adults; they reduce the risk of tripping or falling during everyday locomotion and improve reading efficiency. This study aimed to assess stereopsis level after strabismus surgery in adults who underwent strabismus surgery for any reason.

View Article and Find Full Text PDF

Echocardiography of the right heart in pulmonary arterial hypertension: insights from the ULTRA RIGHT VALUE study.

Eur Heart J Imaging Methods Pract

January 2025

Department of Clinical Internal, Anesthesiological and Cardiovascular Sciences, Sapienza University of Rome, Viale del Policlinico 155, Rome 00161, Italy.

Aims: Outcome in pulmonary arterial hypertension (PAH) is determined by right ventricular (RV) function adaptation to increased afterload. Echocardiography is easily available to assist bedside evaluation of the RV. However, no agreement exists about the feasibility and most relevant measurements.

View Article and Find Full Text PDF

Glucanases are widely applied in industrial applications such as brewing, biomass conversion, food, and animal feed. Glucanases catalyze the hydrolysis of glucan to produce the sugar hemiacetal through hydrolytic cleavage of glycosidic bonds. Current study aimed to investigate structural insights of a glucanase from Clostridium perfringens through blind molecular docking, site-specific molecular docking, molecular dynamics (MD) simulation, and binding energy calculation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!