A high-throughput method has been developed for determining Lewisite [dichloro(2-chlorovinyl)arsine] exposure by measuring the urine metabolite 2-chlorovinylarsonous acid (CVAA) and the oxidized metabolite 2-chlorovinylarsonic acid (CVAOA). The rapid sample preparation included a simple dilution of 400 microL of urine with 40 microL of water and 1 mL of buffer containing an internal standard and brief centrifugation prior to analysis by high-performance liquid chromatography-inductively coupled plasma-mass spectrometry (ICP-MS). CVAOA and CVAA were eluted isocratically with retention factors of approximately 3.0 and 4.2, respectively, from a reversed-phase polar embedded column with a cycle time of 5 min per sample. The dynamic reaction cell, typically used to remove polyatomic isobaric interferences, was not required for ICP-MS analysis because of the resolution of chloride from arsenical peaks of interest. This method was used to detect CVAA and CVAOA in the urine of a rat administered Lewisite up to 24 h after exposure. The method demonstrated linearity over at least three orders of magnitude and had a method detection limit of 1.3 microg/L as CVAA (1.4 microg/L CVAOA). The relative standard deviations for quality control samples ranged from 3 to 6%. The method was sensitive and selective with no false positives in 100 different urine samples collected from individuals with no known exposure to Lewisite. Ninety-six samples could be analyzed in an 8-h day.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/jat/34.3.122 | DOI Listing |
Sensors (Basel)
December 2024
School of Physics and Optoelectronics, Xiangtan University, Xiangtan 411105, China.
In the case of waveguide-based devices, once they are fabricated, their optical properties are already determined and cannot be dynamically controlled, which limits their applications in practice. In this paper, an isosceles triangular-coupling structure which consists of an isosceles triangle coupled with a two-bus waveguide is proposed and researched numerically and theoretically. The coupled mode theory (CMT) is introduced to verify the correctness of the simulation results, which are based on the finite difference time domain (FDTD).
View Article and Find Full Text PDFPolymers (Basel)
December 2024
Department of Chemistry, TUM School of Natural Sciences, Technical University of Munich, Lichtenbergstraße 4, 85748 Garching, Germany.
Polyurethane materials, widely used in indoor environments, occasionally exhibit unpleasant odors. An important source of polyurethane odorants is polyether polyols. Previous studies identified odorous 2-ethyldimethyl-1,3,6-trioxocanes in polyurethane materials and polyols but did not investigate the odor activity of the individual isomers.
View Article and Find Full Text PDFPolymers (Basel)
December 2024
School of Biomedical Engineering and Imaging, Xianning Medical College, Hubei University of Science and Technology, Xianning 437100, China.
Powder-based hemostatic materials have offered unprecedented opportunities for the effective sealing and repair of irregularly shaped wounds and high-pressure, noncompressible arterial bleeding wounds caused by surgeries, traffic accidents, and wartime injuries. However, inadequate adhesion to bleeding wounds and poor hemostasis in biological tissues remains challenging. Herein, we report a self-gelling hemostatic powder based on polyacrylic acid/polyethyleneimine/polyethylene glycol (named PPG) for rapid hemostasis and effective antibacterial ability.
View Article and Find Full Text PDFToxics
December 2024
Center for Global Health, School of Public Health, Nanjing Medical University, Nanjing 211166, China.
Methamphetamine (METH) abuse disrupts the homeostasis of neurotransmitter (NT) metabolism, contributing to a wide range of neurological and psychological disorders. However, the specific effects of METH on NT metabolism, particularly for the tryptophan (TRP) and tyrosine (TYR) metabolic pathways, remain poorly understood. In this study, serum samples from 78 METH abusers and 79 healthy controls were analyzed using Ultra-High-Performance Liquid Chromatography with Tandem Mass Spectrometry (UHPLC-MS/MS).
View Article and Find Full Text PDFToxics
November 2024
Department of Food Analysis and Nutrition, Faculty of Food and Biochemical Technology, University of Chemistry and Technology, Prague, Technicka 3, 166 28 Prague, Czech Republic.
The level of the human body's burden of benzophenone and camphor ultraviolet (UV) filters can be estimated from their urinary levels. The present study describes the implementations and validation of the sensitive analytical method for the analysis of seven benzophenone and two camphor UV filters in urine. Sample preparation includes overnight enzymatic hydrolysis and ethyl acetate extraction followed by purification by dispersive solid-phase extraction using a sorbent Z-Sep.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!