Study Design: This is a retrospective study.
Purpose: We wanted to evaluate the clinical results of surgical and conservative treatment for cervical tear drop fracture.
Overview Of Literature: The tear drop fracture of the lower cervical spine is generally associated with a high incidence of neurological deficits and surgery is needed to treat this injury. Tear drop fracture of C2 is usually a stable fracture that is amendable to conservative treatment.
Methods: We reviewed the outcomes of 25 patients. Cervical tear drop fracture was classified as the extension and flexion types according to the mechanism of injury. The neurologic symptoms were evaluated by the Frankel classification system, and the loss of lordosis and disc height, and the duration of bony union were analyzed.
Results: Twenty one patients had the flexion type injury and 4 patients had the extension type injury. All the patients with the flexion type were treated by anterior decompression and plate stabilization. All the patients with the extension type were treated conservatively. Ten patients with the flexion type had neurologic deficits. The nerve root injuries recovered fully and the incomplete injuries had an average 1.5 grade recovery. Radiologically, the extension type fracture showed bony union at an average of 12.8 weeks. For the patients with the flexion type fracture, the loss of lordosis was 2.6 degrees and the loss of disc height was 2.1 mm. The period of bony union in 20 cases was 13.0 weeks.
Conclusions: Anterior plate stabilization was an effective treatment for the flexion type tear drop fracture. Conservative treatment is thought to be one of the good clinical methods for treating the extension type tear drop fracture.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2852077 | PMC |
http://dx.doi.org/10.4184/asj.2009.3.2.73 | DOI Listing |
Cornea
November 2024
Department of Ophthalmology and Visual Sciences, University of Louisville, Louisville, KY.
Purpose: To visualize the behavior of perfluorohexyloctane (PFHO), an eye drop to treat dry eye disease (DED), on the surface of saline in vitro and on the human ocular surface using infrared emissivity.
Methods: Emissivity videos were used to measure the spreading and disappearance rates of PFHO on saline (with and without mucin for spreading rate) and layered over a 125 nm film of meibum on the surface of saline using a TearView camera. Ocular surface emissivity was videoed in a volunteer without DED before and after instillation of 1 drop of PFHO.
Sci Rep
January 2025
Department of Ophthalmology, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, 134 Dongjie Rd, Fuzhou, 350001, Fujian, China.
With the growing global challenge of drug abuse, there is an urgent need for rapid, accurate, and cost-effective drug detection methods. This study introduces an innovative approach to drug abuse screening by quickly detecting ephedrine (EPH) in tears using drop coating deposition-surface enhanced Raman spectroscopy (DCD-SERS) combined with machine learning (ML). Using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), the average concentration of EPH in tear fluid of Sprague-Dawley (SD) rats, measured over 3 h post-injection, was 1235 ng/mL.
View Article and Find Full Text PDFOptom Vis Sci
December 2024
Department of Biostatistics, LV Prasad Eye Institute, Hyderabad, Telangana, India.
Significance: Artificial tears remain the cornerstone for managing dry eye disease. The current study's real-world efficacy test of carboxymethylcellulose (CMC), polyethylene glycol (PEG) 400, or sodium hyaluronate (SH)-based lubricants highlights their similar effects on noninvasive tear film parameters over the short term. However, patients reported better relief with SH-based lubricants.
View Article and Find Full Text PDFIndian J Ophthalmol
January 2025
Department of Pharmacology, All India Institute of Medical Sciences, Guwahati, Assam, India.
The Schirmer strip measures tear volume in millimeters. A major limitation of the Schirmer strip is that it does not measure tear volume in a volumetric unit. Furthermore, the linearity range, lower limit of detection (LLOD), and lower limit of quantification (LLOQ) are not established.
View Article and Find Full Text PDFZhen Ci Yan Jiu
December 2024
Department of Acupuncture and Moxibustion, China Japan Friendship Hospital, Beijing 100029.
Objectives: To observe the clinical effect on perimenopausal dry eye disease treated with He's fire needle therapy combined with walnut-shell moxibustion.
Methods: A total of 60 patients with perimenopausal dry eye disease were randomized into an observation group (30 cases) and a control group (30 cases). In the observation group, the pricking technique with fire needle was operated at bilateral Naokong (GB19), Feishu (BL13), Xinshu (BL15), Ganshu (BL18), Pishu (BL20), Shenshu (BL23), 3 times a week, for 4 weeks, and the walnut-shell moxibustion was combined, 30 minutes each time, 3 times a week, for 4 weeks.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!