The biomechanical environment of the optic nerve head (ONH), of interest in glaucoma, is strongly affected by the biomechanical properties of sclera. However, there is a paucity of information about the variation of scleral mechanical properties within eyes and between individuals. We thus used biaxial testing to measure scleral stiffness in human eyes. Ten eyes from 5 human donors (age 55.4+/-3.5 years; mean+/-SD) were obtained within 24h of death. Square scleral samples (6mm on a side) were cut from each ocular quadrant 3-9 mm from the ONH centre and were mechanically tested using a biaxial extensional tissue tester (BioTester 5000, CellScale Biomaterials Testing, Waterloo). Stress-strain data in the latitudinal (toward the poles) and longitudinal (circumferential) directions, here referred to as directions 1 and 2, were fit to the four-parameter Fung constitutive equation W=c(e(Q)-1), where Q=c(1)E(11)(2)+c(2)E(22)(2)+2c(3)E(11)E(22) and W, c's and E(ij) are the strain energy function, material parameters and Green strains, respectively. Fitted material parameters were compared between samples. The parameter c(3) ranged from 10(-7) to 10(-8), but did not contribute significantly to the accuracy of the fitting and was thus fixed at 10(-7). The products cc(1) and cc(2), measures of stiffness in the 1 and 2 directions, were 2.9+/-2.0 and 2.8+/-1.9 MPa, respectively, and were not significantly different (two-sided t-test; p=0.795). The level of anisotropy (ratio of stiffness in orthogonal directions) was 1.065+/-0.33. No statistically significant correlations between sample thickness and stiffness were found (correlation coefficients=-0.026 and -0.058 in directions 1 and 2, respectively). Human sclera showed heterogeneous, near-isotropic, nonlinear mechanical properties over the scale of our samples.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jbiomech.2010.02.031 | DOI Listing |
Int J Mol Sci
January 2025
NDDH, Royal Devon University Healthcare NHS Foundation Trust, Barnstaple EX31 4JB, UK.
Pseudoexfoliation syndrome (PXS) is an age-related fibrillopathy where fibrillar exfoliation material accumulates and deposits in ocular and extra-ocular tissue. Within the eye, this substance accumulates on the ocular surface and in the anterior segment of the eye, impacting ocular structures such as the conjunctiva, Tenon's capsule, sclera, cornea, iris, ciliary body, trabecular meshwork, and lens. This review aims to collate the current literature on how each anatomical part of the eye is affected by PXS, with a strong focus on molecular changes.
View Article and Find Full Text PDFIndian J Ophthalmol
February 2025
Department of Oculoplasty and Oncology Services (Dr. Rajendra Prasad Centre for Ophthalmic Sciences), AIIMS, New Delhi, India.
Background: Involution or aging is the most common cause of lower eyelid entropion (in-turning of eyelid margin) in the elderly population. Various pathomechanisms have been postulated for its occurrence. Aging leads to laxity of tissues and loss of muscle tone.
View Article and Find Full Text PDFCureus
December 2024
Department of Anatomy, A.T. Still University of Health Sciences - Kirksville College of Osteopathic Medicine, Kirksville, USA.
Erythema multiforme major (EMM) is an acute, immune-mediated mucocutaneous disease that rarely affects the genital mucosal surfaces. This study describes a 39-year-old male with this rare disease and unusual presentation. The patient presented to an emergency department with oral lesions, drainage from both eyes, injected sclera, and characteristic targetoid lesions on the face, upper extremities, torso, and plantar surfaces of the feet.
View Article and Find Full Text PDFRetina
February 2025
Department of Ophthalmology, Liyang Hospital of Chinese Medicine, Liyang, China.
Purpose: To describe a custom bent 27-gauge needle-guided suture snare technique for scleral fixation of posterior chamber intraocular lenses (PCIOL).
Methods: An 8-0 polypropylene suture was threaded into the lumen of a custom bent 27-gauge needle, and the needle tip was advanced into the eye from the intraocular lens (IOL) fixation point. The suture was threaded through the posterior limbal incision inside the IOL haptic loop and pulled out.
Cureus
January 2025
Neurosurgery, University of Kinshasa, Kinshasa, COD.
Pediatric spinal tumors include a variety of developmental lesions and uncommon neoplasms that differ significantly from those seen in adults. These conditions are underreported in the sub-Saharan medical literature. We present the case of a 10-year-old girl brought by her family to the University Teaching Hospital of Kinshasa in the Democratic Republic of Congo with progressive lower limb functional impairment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!