Objective: To establish the normative data of sinusoidal harmonic acceleration test (SHAT) and evaluate the value of clinical application.

Methods: One hundred and twenty normal persons, 21 Meniere's disease patients, 2 bilateral vestibular peripheral lesion patients, 15 unilateral vestibular peripheral lesion patients and 10 central lesion patients were tested with SHAT.

Results: The calibration time was longer in the older persons. The phase decreased with the frequency, and the gain increased with the frequency, but the reliability of the re-test of the phase was better in the lower frequency. The results of the 7 Meniere's disease patients without symptoms were normal, 14 patients post-attack revealed abnormal, 11 had phase abnormal, 3 had gain decrease, 10 revealed asymmetry and spontaneous nystagmus simultaneously, 8 patients had two parameters abnormal. The unilateral vestibular peripheral lesion patients showed 73% (11/15) phase abnormal, 67% (10/15) gain decrease and 40% (6/15) asymmetry, while 5/6 asymmetry patients had spontaneous nystagmus. The gain of the bilateral vestibular peripheral lesion patients showed severe decrease. The abnormal rate in central lesion patients were 70% (7/10) in phase, 20% (2/10) in gain and 40% (4/10) in asymmetry, but the patients with asymmetry had no spontaneous nystagmus.

Conclusions: The normal range of the phase, gain and asymmetry of SHAT is in narrow bandwidth. The phase is the most important abnormal sign.

Download full-text PDF

Source

Publication Analysis

Top Keywords

lesion patients
24
vestibular peripheral
16
peripheral lesion
16
patients
12
phase abnormal
12
sinusoidal harmonic
8
harmonic acceleration
8
meniere's disease
8
disease patients
8
bilateral vestibular
8

Similar Publications

Heterotopic pregnancy is defined as the concurrent presence of both an intrauterine pregnancy and an extrauterine (typically ectopic) pregnancy. This report presents the case of a 36-year-old female patient who presented to the emergency department with lower abdominal pain. A comprehensive evaluation, including transabdominal and transvaginal ultrasound imaging, revealed a heterotopic pregnancy at an estimated gestational age of six weeks and two days.

View Article and Find Full Text PDF

Bankart lesions, or anterior-inferior glenoid labral tears, are diagnostically challenging on standard MRIs due to their subtle imaging features-often necessitating invasive MRI arthrograms (MRAs). This study develops deep learning (DL) models to detect Bankart lesions on both standard MRIs and MRAs, aiming to improve diagnostic accuracy and reduce reliance on MRAs. We curated a dataset of 586 shoulder MRIs (335 standard, 251 MRAs) from 558 patients who underwent arthroscopy.

View Article and Find Full Text PDF

Whole-body PET imaging is often hindered by respiratory motion during acquisition, causing significant degradation in the quality of reconstructed activity images. An additional challenge in PET/CT imaging arises from the respiratory phase mismatch between CT-based attenuation correction and PET acquisition, leading to attenuation artifacts. To address these issues, we propose two new, purely data-driven methods for the joint estimation of activity, attenuation, and motion in respiratory self-gated TOF PET.

View Article and Find Full Text PDF

Objectives: Rotator cuff tendinitis (RCT) is a tendon inflammation often following subacromial impingement syndrome. One of the non-surgical management modalities for RCT is subacromial injection of corticosteroids. Some studies have claimed a correlation between ACTH (Adrenocorticotropic Hormone) deficiency and rotator cuff lesions; hence, intramuscular ACTH analogue injection has been recommended as an option.

View Article and Find Full Text PDF

CT-guided adaptive radiotherapy (ART) for the treatment of pancreatic adenocarcinoma is rapidly increasing and has been shown to provide advanced treatment tools comparable to magnetic resonance imaging (MRI)-guided adaptive therapy. Here, we provide the first case report of a local pancreatic recurrence treatment after definitive resection using cone beam computed tomography (CBCT)-guided ART (CT-guided ART) enabled by HyperSight imaging (Varian Medical Systems, Inc., Palo Alto, CA, USA) for daily delineation of organs-at-risk (OARs) and target to improve the quality of online ART.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!