Objective: To evaluate coronary stents in vitro using 128-slice-dual-source computed tomography (CT).
Methods: Twelve different coronary stents placed in a non-moving cardiac/chest phantom were examined by 128-slice dual-source CT using three CT protocols [high-pitch spiral (HPS), sequential (SEQ) and conventional spiral (SPIR)]. Artificial in-stent lumen narrowing (ALN), visible inner stent area (VIA), artificial in-stent lumen attenuation (ALA) in percent, image noise inside/outside the stent and CTDIvol were measured.
Results: Mean ALN was 46% for HPS, 44% for SEQ and 47% for SPIR without significant difference. Mean VIA was similar with 31% for HPS, 30% for SEQ and 33% for SPIR. Mean ALA was, at 5% for HPS, significantly lower compared with -11% for SPIR (p = 0.024), but not different from SEQ with -1%. Mean image noise was significantly higher for HPS compared with SEQ and SPIR inside and outside the stent (p < 0.001). CTDIvol was lower for HPS (5.17 mGy), compared with SEQ (9.02 mGy) and SPIR (55.97 mGy), respectively.
Conclusion: The HPS mode of 128-slice dual-source CT yields fewer artefacts inside the stent lumen compared with SPIR and SEQ, but image noise is higher. ALN is still too high for routine stent evaluation in clinical practice. Radiation dose of the HPS mode is markedly (less than about tenfold) reduced.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-010-1792-9 | DOI Listing |
Diagnostics (Basel)
December 2024
Department of Radiology, Innsbruck Medical University, 6020 Innsbruck, Austria.
: Left atrial (LA) fibrosis imaging improves the guidance of LA catheter ablation. Cardiac computed tomography (CT) may be a reasonable alternative to CMR. The aim was to evaluate late enhancement (LE) fibrosis mapping by CT, and to correlate the results with low-voltage areas on electroanatomical mapping (EAM).
View Article and Find Full Text PDFLancet Reg Health Southeast Asia
October 2024
Paediatric Allergy Immunology Unit, Department of Pediatrics, Advanced Paediatrics Centre, Post Graduate Institute of Medical Education and Research, Chandigarh 160012, India.
J Clin Med
August 2024
Department of Cardiology, Angiology, Pneumology and Internal Intensive Care, Ulm University Heart Center, 89081 Ulm, Germany.
Before surgical or transcatheter aortic valve implantation (TAVI), coronary status evaluation is required. The role of combined computed coronary tomography angiography (cCTA) and TAVI planning CT in this context is not yet well elucidated. This study assessed whether relevant proximal coronary disease requiring coronary revascularization can be safely detected by combined cCTA and TAVI planning CT, including CT-derived fractional flow reserve (FFR) calculation in patients with severe aortic stenosis.
View Article and Find Full Text PDFPol J Radiol
June 2024
Department of Radiology and Radiodiagnostics, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Katowice, Poland.
Pol J Radiol
February 2024
Department of Cardiology and Electrotherapy, Silesian Centre for Heart Diseases, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Katowice, Poland.
Purpose: Anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA) is a rare congenital ano-maly of the origin of the coronary arteries. The prevalence of this anomaly in the adult patient population is low, and therefore there is virtually no original research on this topic. Reports are limited to case reports.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!