Effects of region and sex on the mechanical properties of the glenohumeral capsule during uniaxial extension.

J Appl Physiol (1985)

Musculoskeletal Research Center, Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, 405 Center for Bioengineering, 300 Technology Dr., Pittsburgh, PA 15219, USA.

Published: June 2010

Surgical repair of the glenohumeral capsule after dislocation ignores regional boundaries of the capsule and is not sex specific. However, each region of the capsule functions to stabilize the joint in different positions, and differences in joint laxity between men and women have been found. The objectives of this research were to determine the effects of region (axillary pouch and posterior capsule) and sex on the material properties of the glenohumeral capsule. Boundary conditions derived from experiments were used to create finite-element models that applied tensile deformations to tissue samples from the capsule. The material coefficients of a hyperelastic constitutive model were determined via inverse finite-element optimization, which minimized the difference between the experimental and finite-element model-predicted load-elongation curve. These coefficients were then used to create stress-stretch curves representing the material properties of the capsule regions for each sex in response to uniaxial extension. For the axillary pouch, the C1 (men: 0.28+/-0.39 MPa and women: 0.23+/-0.12 MPa) and C2 (men: 8.2+/-4.1 and women: 7.7+/-3.0) material coefficients differed between men and women by only 0.05 MPa and 0.5, respectively. Similarly, the posterior capsule coefficients differed by 0.15 MPa (male: 0.49+/-0.26 MPa and female: 0.34+/-0.20 MPa) and 0.6 (male: 7.8+/-2.9 and female: 7.2+/-3.0), respectively. No differences could be detected in the material coefficients between regions or sexes. As a result, surgeons may not need to consider region- and sex-specific surgical repair techniques. Furthermore, finite-element models of the glenohumeral joint may not need region- or sex-specific material coefficients when using this constitutive model.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2886678PMC
http://dx.doi.org/10.1152/japplphysiol.01175.2009DOI Listing

Publication Analysis

Top Keywords

material coefficients
16
glenohumeral capsule
12
capsule
9
effects region
8
properties glenohumeral
8
uniaxial extension
8
surgical repair
8
capsule sex
8
men women
8
axillary pouch
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!