It is demonstrated that silver nanoparticle (SNP) arrays fabricated by combining nanoimprint lithography and electrochemical deposition methods can be used as substrates for metal-enhanced fluorescence, which is widely used in optics, sensitive detection, and bioimaging. The method presented here is simple and efficient at controlling the nanoparticle density and interparticle distance within one array. Furthermore, it is found that the fluorescence intensity can be tuned by engineering the feature size of the SNP arrays. This is due to the different coupling efficiency between the emission of the fluorophores and surface plasmon resonance band of the metallic nanostructures.

Download full-text PDF

Source
http://dx.doi.org/10.1002/smll.200902350DOI Listing

Publication Analysis

Top Keywords

metal-enhanced fluorescence
8
silver nanoparticle
8
snp arrays
8
tuning intensity
4
intensity metal-enhanced
4
fluorescence engineering
4
engineering silver
4
nanoparticle arrays
4
arrays demonstrated
4
demonstrated silver
4

Similar Publications

Although fluorescence analysis methods are widely used in pesticide residue detection, improving their sensitivity and selectivity remains a challenge. This paper presents a novel ratio fluorescence sensor based on the molecular imprinting polymers (MIPs) and metal-enhanced fluorescence for visual detection of dicamba (DIC). Calcium fluoride (CaF) quantum dots (QDs) were immobilized on the surface of Ag@MIPs, resulting in a blue fluorescence response signal (Ag@MIPs-CaF).

View Article and Find Full Text PDF

Detection and Quantification of DNA by Fluorophore-Induced Plasmonic Current: A Novel Sensing Approach.

Sensors (Basel)

December 2024

Department of Chemistry and Biochemistry, Institute of Fluorescence, University of Maryland, Baltimore County, 701 E Pratt St, Baltimore, MD 21202, USA.

We report on the detection and quantification of aqueous DNA by a fluorophore-induced plasmonic current (FIPC) sensing method. FIPC is a mechanism described by our group in the literature where a fluorophore in close proximity to a plasmonically active metal nanoparticle film (MNF) is able to couple with it, when in an excited state. This coupling produces enhanced fluorescent intensity from the fluorophore-MNF complex, and if conditions are met, a current is generated in the film that is intrinsically linked to the properties of the fluorophore in the complex.

View Article and Find Full Text PDF
Article Synopsis
  • Diverse analytical techniques are needed to study microplastics (MPs) since current methods struggle to detect smaller sizes, particularly those under 5 μm.
  • The study introduces a new method called MicroMetaSense, which uses metal-enhanced fluorescence to detect a wide range of MPs at extremely low concentrations, achieving a sensitivity of 183-205 femtograms.
  • This approach is cost-effective, efficient, and significantly improves detection capabilities, marking a significant advancement in monitoring microplastics in both lab and environmental samples.
View Article and Find Full Text PDF

Research has shown that the expression level of microRNA-155 (miRNA-155) is positively correlated with clinical stage and depth of invasion in patients with cervical cancer and cervical intraepithelial neoplasia and tends to be highly expressed. Therefore, it is very important to develop sensitive miRNA-155 analysis methods for the early diagnosis, treatment, and prognostic evaluation of cervical cancer. In this study, a near-infrared light-driven fluorescent biosensor based on the metal-enhanced fluorescence effect of polydopamine-coated upconversion nanoparticle (UP/Au) and two toehold-mediated strand displacement (TMSD) steps was constructed for the detection of miRNA-155.

View Article and Find Full Text PDF

The outbreak of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) which was first reported in early January 2020, continues to devastate the worlds public health system. Herein, we report on the development of a novel metal-enhanced fluorescence (MEF) and electrochemical biosensor for SARS-CoV-2 spike (S) protein. To develop the MEF biosensor, SiO-coated Si-doped ZnSeS quantum dots (QDs) were newly synthesized and conjugated to an aptamer-molecular beacon (Apta-MB) probe.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!