Purpose: To assess reliability of wall shear stress (WSS)calculations using computational fluid dynamics (CFD) dependent on inflow in internal carotid artery aneurysms (ICA).
Materials And Methods: Six unruptured ICA aneurysms were studied. 3D computational meshes were created from 3D digital subtraction angiographic images (Axiom Artis dBA, Siemens Medical Solutions). Transient CFD simulations(Fluent, ANSYS Inc.) were performed for two inflow conditions: (1) idealized averaged waveform from normal subjects (ID) and (2) patient-specific waveform (PS)measured with 2D phase contrast magnetic resonance imaging. Stability of calculation was assessed by comparing mean WSS (
Results: For all cases, mean relative difference (PS-ID) of WSS (
Conclusion: For accurate calculations of WSS parameters,patient-specific information on physiological flow may be necessary. Results obtained with averaged or idealized flow waveforms may have to be interpreted with caution.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00701-010-0647-0 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!