Performance evaluation of diagnostic radiology dosimeters in clinical and calibration x-ray beams.

Health Phys

Ionizing Radiation Calibration Laboratory, Greek Atomic Energy Commission, 15310 Agia Paraskevi, Athens, Attiki, Greece.

Published: May 2010

Diagnostic radiology dosimeters should comply with International Electrotechnical Commission (IEC) 61674 standard in order to perform measurements with sufficient accuracy and reliability. The calibration of a dosimeter is performed under, and pertains to, reference conditions. However, in most cases, dosimeters are used for clinical measurements under non-reference conditions. The performance, in terms of accuracy of dose measurements, of six commercial diagnostic radiology dosimeters was tested at reference calibration and at clinical non-reference conditions. The results showed that all dosimeters being tested exhibited limits of variation within the +/-5% IEC limits. Depending on the detector's physical and operational properties, the dosimeters' energy dependence of response values varied from -4.7% to +4.2%. To address this variation of response, calibration at three radiation qualities (RQR 3, RQR 5, and RQR 9), at least, is recommended. Different irradiation conditions such as air kerma rate, x-ray tube design, x-ray system, and dosimeter operational modes affect the dosimeters' response by less than 3%. A dosimeter that complies with IEC standards and operates according to its specifications could be used at typical clinical irradiation conditions taking into account only corrections for the energy dependence of response. In this case, the error in dose accuracy is expected to be less than 3%.

Download full-text PDF

Source
http://dx.doi.org/10.1097/HP.0b013e3181d18d45DOI Listing

Publication Analysis

Top Keywords

diagnostic radiology
12
radiology dosimeters
12
dosimeters clinical
8
non-reference conditions
8
dosimeters tested
8
energy dependence
8
dependence response
8
rqr rqr
8
irradiation conditions
8
dosimeters
5

Similar Publications

Magnetic Resonance Imaging (MRI) safety is a critical concern in the Asia-Oceania region, as it is elsewhere in the world, due to the unique and complex MRI environment that demands attention. This call-for-action outlines ten critical steps to enhance MRI safety and promote a culture of responsibility and accountability in the Asia-Oceania region. Key focus areas include strengthening education and expertise, improving quality assurance, fostering collaboration, increasing public awareness, and establishing national safety boards.

View Article and Find Full Text PDF

Associations of fat, bone, and muscle indices with disease severity in patients with obstructive sleep apnea hypopnea syndrome.

Sleep Breath

January 2025

Department of Pulmonary and Critical Care Medicine, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, No.1 Da Hua Road, Dong Dan, Dongcheng District, Beijing, 100730, PR China.

Purpose: To investigate the relationship between obstructive sleep apnea hypopnea syndrome (OSAHS) severity and fat, bone, and muscle indices.

Methods: This study included 102 patients with OSAHS and retrospectively reviewed their physical examination data. All patients underwent polysomnography, body composition analysis, dual-energy X-ray absorptiometry, computed tomography (CT) and blood test.

View Article and Find Full Text PDF

Objective: Using F-FDG PET/CT metabolic parameters to differentiate post-transplant lymphoproliferative disorder (PTLD) and reactive lymphoid hyperplasia (RLH), and PTLD subtypes.

Methods: F-FDG PET/CT and clinical data from 63 PTLD cases and 19 RLH cases were retrospectively collected. According to the 2017 WHO classification, PTLD was categorized into four subtypes: nondestructive (ND-PTLD), polymorphic (P-PTLD), monomorphic (M-PTLD), and classic Hodgkin.

View Article and Find Full Text PDF

Objectives: To assess the effect of patient positioning and general anesthesia on the condylar position in orthognathic surgery.

Materials And Methods: This prospective study included patients undergoing orthognathic surgery between 2019 and 2020. Four weeks prior to surgery (T0) cone-beam computed tomography (CBCT) scans and intra-oral scans (IOS) were acquired in an upright position.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!