A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Selected performance characteristics of the Roche Elecsys testosterone II assay on the Modular analytics E 170 analyzer. | LitMetric

AI Article Synopsis

  • The Roche Testo II testosterone immunoassay effectively measures testosterone levels with high precision and linearity, outperforming previous immunoassays for women and children.
  • Results showed a limit of blank (LoB) of 0.07 nmol/l and total imprecision under 6%, indicating reliability in tests conducted.
  • While it performed comparably for men, there are still challenges in accurately quantifying lower testosterone concentrations for men and children using this immunoassay.

Article Abstract

Background: Serum testosterone measurements have utility in diagnosis of clinical conditions characterized by both increased and decreased testosterone concentrations. Studies have indicated that testosterone immunoassays may give inaccurate results for women and children. We evaluated the performance of a second generation testosterone immunoassay from Roche Diagnostics.

Methods: Testo II performed on a Modular Analytics E 170 analyzer is an automated random access electrochemiluminometric assay. We evaluated limit of blank (LoB), imprecision, linearity, interference, and method comparison with liquid chromatography-tandem mass spectrometry assay (LC-MS/MS). Method comparison included the current generation Roche testosterone assay (Testo I) and the Access 2 testosterone chemiluminometric assay (Beckman Coulter). Results for men and women were analyzed for analytic concordance. The relative % differences of immunoassay compared to LC-MS/MS results were evaluated.

Results: The LoB was 0.07nmol/l. Total imprecision was <6%. The assay was linear from 0.2 to 46.6nmol/l. Negative interference was observed for lipemia at concentrations >22.5g/l. Analytic concordance showed improved specificity for women. Comparison of results to LC-MS/MS indicated comparable performance with other immunoassays for men and improved performance for women, boys, and girls with mean differences of 0.5%, -0.7%, and 24.4%, respectively.

Conclusions: The Roche Testo II assay demonstrated excellent precision. Comparison to 2 other automated immunoassays showed comparable performance for men and improved performance for women and children. However, challenges still exist for quantifying testosterone concentrations <10.4nmol/l for men and <1.7nmol/l for women and children by immunoassay.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cca.2010.03.041DOI Listing

Publication Analysis

Top Keywords

testosterone
8
testosterone assay
8
modular analytics
8
analytics 170
8
170 analyzer
8
testosterone concentrations
8
women children
8
method comparison
8
analytic concordance
8
comparable performance
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!