ToF-SIMS Depth Profiling of Organic Films: A Comparison between Single Beam and Dual-beam Analysis.

J Phys Chem C Nanomater Interfaces

National ESCA and Surface Analysis Center for Biomedical Problems, University of Washington, Department of Chemical Engineering, Box 351750, Seattle, WA 98195.

Published: January 2010

In dual-beam depth profiling, a high energy analysis beam and a lower energy etching beam are operated in series. Although the fluence of the analysis beam is usually kept well below the static SIMS limit, complete removal of the damage induced by the high energy analysis beam while maintaining a good depth resolution is difficult. In this study a plasma polymerized tetraglyme film is used as the model organic system and the dimensionless parameter R, (analysis beam fluence)/(total ion fluence), is introduced to quantify the degree of sample damage induced as a function of the analysis beam fluence. It was observed for a constant C(60) (+) etching beam fluence, increasing the analysis fluence (and consequently increasing the R parameter) increased in the amount of damage accumulated in the sample. For Bi(n) (+) (n = 1 and 3) and C(60) (+) depth profiling, minimal damage accumulation was observed up to R = 0.03, with a best depth resolution of 8 nm. In general, an increase in the Bi(n) (+) analysis fluence above this value resulted in a decrease in the molecular signals of the steady state region of the depth profile and a degradation of the depth resolution at the polymer/substrate interface.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2850126PMC
http://dx.doi.org/10.1021/jp9066179DOI Listing

Publication Analysis

Top Keywords

analysis beam
20
depth profiling
12
depth resolution
12
beam
8
analysis
8
high energy
8
energy analysis
8
etching beam
8
damage induced
8
beam fluence
8

Similar Publications

Purpose: The greater palatine foramen (GPF) represents the inferior opening of the greater palatine canal and is located posterolaterally on both sides of the hard palate. The aim of this study is to morphometrically characterise the GPF and to determine its anatomical relationships in a Portuguese population.

Methods: A retrospective study was performed based on the clinical records which included all permanent teeth erupted and a cone beam computed tomography (CBCT) of the entire maxilla.

View Article and Find Full Text PDF

Goal of the present study was to develop and build a phantom that replicates the air gaps under a gel bolus and to estimate the surface dose (D) under normal incidence with a 6 MV photon beam. For this, an acrylic phantom with 10 plates, each including five open slots (one in the centre and four off axis) with a size of 2 cm × 2 cm at depths of 0.54 cm, 0.

View Article and Find Full Text PDF

A fused-silica three-port grating under TE-polarized normal incidence is designed and manufactured with improved diffraction efficiency (DE) and bandwidth. A physical explanation of the grating diffraction is provided using the simplified mode method (SMM), and parameters of the grating structure were optimized using rigorous coupled-wave analysis (RCWA). For a given set of optimized parameters, a transmitted three-port grating with an area of 170 ×170 was fabricated by scanning beam interference lithography (SBIL), and diffraction properties were investigated.

View Article and Find Full Text PDF

Preclinical and First-In-Human Imaging of Novel [F]F-FAPI-FUSCC-07 Tracer: Comparative Prospective Study with [F]F-FAPI-42 and [F]F-FAPI-74.

Mol Pharm

January 2025

Department of Nuclear Medicine, Fudan University Shanghai Cancer Center; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032, China.

This study aimed to develop and evaluate a novel fibroblast activation protein (FAP)-specific tracer, fluorine-18-labeled fibroblast activation protein inhibitor-FUSCC-07 ([F]F-FAPI-FUSCC-07), for use in both preclinical and clinical settings. Preclinical evaluations were conducted to assess the stability and partition coefficient of [F]F-FAPI-FUSCC-07. Experiments involving human glioma U87MG cells demonstrated its cellular uptake and inhibitory properties.

View Article and Find Full Text PDF

Background/purpose: There is no study available addressing the relationship between orbital volume (OV) and skeletal patterns. The purpose of this study was to investigate the correlations between the OV and patient's characteristics (sex, age, height, and skeletal patterns) of Taiwanese adults.

Materials And Methods: Cone-beam computed tomography images of 94 individuals (men: 47; women: 47) were analyzed to measure their OV and maxillary dimensions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!