Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A fast, sensitive, universal and accurate method for the determination of four different tyrosine kinase inhibitors from biological material was developed using LC-MS/MS techniques. Utilizing a simple protein precipitation with acetonitrile a 20 microl sample volume of biological matrixes can be extracted at 4 degrees C with minimal effort. After centrifugation the sample extract is introduced directly onto the LC-MS/MS system without further clean-up and assayed across a linear range of 1-4000 ng/ml. Chromatography was performed using a Dionex Ultimate 3000 with a Phenomenex prodigy ODS3 (2.0 mm x 100 mm, 3 microm) column and eluted at 200 microl/min with a tertiary mobile phase consisting of 20mM ammonium acetate:acetonitrile:methanol (2.5:6.7:8.3%). Injection volume varied from 0.1 microl to 1 microl depending on the concentration of the drug observed. Samples were observed to be stable for a maximum of 48 h after extraction when kept at 4 degrees C. Detection was performed using a turbo-spray ionization source and mass spectrometric positive multi-reaction-monitoring-mode (+MRM) for Gefitinib (447.1 m/z; 127.9 m/z), Erlotinib (393.9 m/z; 278.2 m/z), Sunitinib (399.1 m/z; 283.1 m/z) and Sorafenib (465.0 m/z; 251.9 m/z) at an ion voltage of +3500 V. The accuracy, precision and limit-of-quantification (LOQ) from cell culture medium were as follows: Gefitinib: 100.2+/-3.8%, 11.2 nM; Erlotinib: 101.6+/-3.7%, 12.7 nM; Sunitinib: 100.8+/-4.3%, 12.6 nM; Sorafenib: 93.9+/-3.0%, 10.8 nM, respectively. This was reproducible for plasma, whole blood, and serum. The method was observed to be linear between the LOQ and 4000 ng/ml for each analyte. Effectiveness of the method is illustrated with the analysis of samples from a cellular accumulation investigation and from determination of steady state concentrations in clinically treated patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jchromb.2010.03.010 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!