Aim: To compare the diagnostic accuracy and sensitivity of gadoxetic acid-enhanced MRI and superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance imaging (MRI) for the detection of hepatocellular carcinoma (HCC).

Materials And Methods: Eighty-nine patients (118 HCCs) who underwent three-dimensional gadoxetic acid-enhanced MRI and SPIO-enhanced MRI with a mean interval of 4.7 days (range 3-7 days), were included in this study. Two observers reviewed the gadoxetic acid set (unenhanced, early dynamic, 10 and 20 min hepatocyte-phase images) and SPIO set [unenhanced and ferucarbotran-enhanced T1-, T2-turbo spin-echo (TSE), and T2* weighted imaging (WI)] in consensus. Diagnostic accuracy and sensitivity were evaluated using the alternative-free response receiver operator characteristic (ROC) method.

Results: The area under ROC curve (Az value) and sensitivity of the gadoxetic acid set (Az 0.964; sensitivity 90.7%) were significantly higher than those of the SPIO set (Az 0.830; sensitivity 84.7%; p<0.05). There were 14 and seven lesions that were verified only on the gadoxetic acid set and only on the SPIO set, respectively. Four HCCs were clearly revealed as hypointense only on gadoxetic acid-enhanced hepatocyte phase imaging, but were occult on other sequences, including the SPIO set.

Conclusion: Gadoxetic acid-enhanced MRI is better than SPIO-enhanced MRI for the detection of HCCs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.crad.2009.11.012DOI Listing

Publication Analysis

Top Keywords

gadoxetic acid-enhanced
12
acid-enhanced mri
12
mri superparamagnetic
8
superparamagnetic iron
8
mri detection
8
detection hepatocellular
8
hepatocellular carcinoma
8
diagnostic accuracy
8
accuracy sensitivity
8
sensitivity gadoxetic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!