We describe a case with pacemaker implantation for cardiac resynchronization therapy (CRT) in a patient with complex congenital heart disease, facilitated by cardiac computed tomography (CT) and coronary sinus (CS) venography. A 37-year-old male presented with congenitally corrected transposition of the great arteries and mesocardia, along with a history of two open heart surgeries (closure of atrial septal defects and a ventricular septal defect, and pulmonary valvectomy at age 7; mechanical tricuspid valve replacement at age 13). He showed symptoms of progressive heart failure (NYHA class III) with significant impairment of the systemic right ventricular function. He also developed permanent atrial fibrillation with a junctional rhythm at a rate of 45 beats per minute. Biventricular pacing without an atrial lead was considered to be the best option available. CRT implantation was facilitated by proper identification of CS anatomy utilizing cardiac CT and CS venography and was performed without any complications. At follow up, a postero-anterior chest X-ray showed the final position of the right-sided ventricular (left ventricular morphology) lead pointing to the apex and the left ventricular lead at the posterolateral aspect of the systemic ventricle (right ventricular morphology).
Download full-text PDF |
Source |
---|
BAY 2413555 is a novel selective and reversible positive allosteric modulator of the type 2 muscarinic acetylcholine (M2) receptor, aimed at enhancing parasympathetic signaling and restoring cardiac autonomic balance for the treatment of heart failure (HF). This study tested the safety, tolerability and pharmacokinetics of this novel therapeutic option. REMOTE-HF was a multicenter, double-blind, randomized, placebo-controlled, phase Ib dose-titration study with two active arms.
View Article and Find Full Text PDFTurk J Med Sci
December 2024
Deputy Health Minister, Ministry of Health, Ankara, Turkiye.
Background/aim: Effective management of heart failure involves evidence-based use of multiple medications and their combinations. Furthermore, dosage escalation of the recommended medications is advised. In cases of advanced heart failure, long-term mechanical assistance devices or heart transplantation surgery may be necessary.
View Article and Find Full Text PDFPacing Clin Electrophysiol
December 2024
Arrhythmia Unit, Department of Cardiology, Hospital Juan Ramón Jiménez, Huelva, Spain.
Background: Interventricular dyssynchrony derived from the classic non-physiological stimulation (n-PS) of the right ventricle (RV) is a known cause of left ventricular dysfunction (LVDys).
Methods: This was a prospective descriptive single-center study. We analyzed patients who develop LVDys with n-PS, and the results after upgrading to conduction system pacing (CSP).
Coron Artery Dis
October 2024
Department of Cardiology, Kocaeli City Hospital, Kocaeli, Turkey.
Cureus
November 2024
Department of Cardiology, Liv Hospital Ulus, Istanbul, TUR.