A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A pneumatic glove and immersive virtual reality environment for hand rehabilitative training after stroke. | LitMetric

While a number of devices have recently been developed to facilitate hand rehabilitation after stroke, most place some restrictions on movement of the digits or arm. Thus, a novel glove was developed which can provide independent extension assistance to each digit while still allowing full arm movement. This pneumatic glove, the PneuGlove, can be used for training grasp-and-release movements either with real objects or with virtual objects in a virtual reality environment. Two groups of stroke survivors, with seven subjects in each group, completed a six-week rehabilitation training protocol, consisting of three 1-h sessions held each week. One group wore the PneuGlove during training, performed both within a novel virtual reality environment and outside of it with physical objects, while the other group completed the same training without the device. Across subjects, significant improvements were observed in the Fugl-Meyer Assessment for the upper extremity (p < 0.001), the hand/wrist portion of the Fugl-Meyer Assessment (p < 0.001), the Box and Blocks test (p < 0.005), and palmar pinch strength (p < 0.005). While changes in the two groups were not statistically different, the group using the PneuGlove did show greater mean improvement on each of these measures, such as gains of 3.7 versus 2.4 points on the hand/wrist portion of the Fugl-Meyer Assessment and 14 N versus 5 N in palmar pinch.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TNSRE.2010.2047588DOI Listing

Publication Analysis

Top Keywords

virtual reality
12
reality environment
12
fugl-meyer assessment
12
pneumatic glove
8
pneuglove training
8
objects virtual
8
group completed
8
hand/wrist portion
8
portion fugl-meyer
8
palmar pinch
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!