We report on single-photon interference experiments in a Michelson-type interferometer built with two 6-km-long fiber spools, as well as on the active stabilization of the interferometer. A weak coherent light signal was (de-) multiplexed with a strong reference light using wavelength-division multiplexing technique, and real-time feedback control technique was applied for the reference light to actively stabilize the phase fluctuation in the long-armed fiber interferometer. The stabilized interferometer showed phase stability of 0.06 rad, which corresponds to an optical path length fluctuation of 15 nm between the 6-km-long interfering arms. The raw visibility obtained without subtracting noise counts in the single-photon interference experiment was more than 98% for stabilized conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.17.019027DOI Listing

Publication Analysis

Top Keywords

single-photon interference
8
reference light
8
interferometer
5
stabilization long-armed
4
long-armed fiber-optic
4
fiber-optic single-photon
4
single-photon interferometer
4