Clip, coil, or cut.

Clin Gastroenterol Hepatol

Department of Medicine, Metro Health Medical Center, Case Western Reserve University, Cleveland, Ohio, USA.

Published: October 2010

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cgh.2010.03.026DOI Listing

Publication Analysis

Top Keywords

clip coil
4
coil cut
4
clip
1
cut
1

Similar Publications

Microsurgical clipping remains a viable option for the treatment of coilable ruptured middle cerebral artery aneurysms in the endovascular era.

Neurosurg Rev

January 2025

Department of Neurosurgery, Korea University Ansan Hospital, Korea University College of Medicine, 123 Jeokgeum-ro, Danwon-gu, 15355, Ansan, Gyeonggi-do, South Korea.

Although many institutions increasingly perform endovascular coiling instead of microsurgical clipping as the primary treatment for ruptured aneurysms, there remains ongoing debate regarding the optimal treatment strategy for ruptured middle cerebral artery (MCA) aneurysms. Therefore, we compared the outcomes of clipping and coiling for treating ruptured MCA aneurysms. A total of 155 ruptured MCA aneurysms that were deemed eligible for both clipping and coiling were retrospectively reviewed.

View Article and Find Full Text PDF

Background: Aneurysmal subarachnoid hemorrhage (aSAH) carries a high economic cost and clinical morbidity in the United States. Beyond prolonged admissions and poor post-injury functional status, there is an additional cost of chronic shunt-dependent hydrocephalus for many aSAH patients. Adjuvant lumbar drain (LD) placement has been hypothesized to promote clearance of subarachnoid blood from the cisternal space, with an ultimate effect of decreasing shunt placement rates.

View Article and Find Full Text PDF

Objective: In this study, changes in treatment methods and patient prognosis were analyzed using a Korean nationwide medical insurance information database.

Methods: Patients with subarachnoid hemorrhage who received surgical treatment for cerebral aneurysm from 2005 to 2020 were included. The specific surgery type was classified using the surgical code and according to whether stents were used.

View Article and Find Full Text PDF

Background: To investigate the artifact sizes of four common breast clip-markers on a standard breast magnetic resonance imaging (MRI) protocol in an in vitro phantom model.

Methods: Using 1.5-T and 3-T whole-body scanners with an 18-channel breast coil, artifact dimensions of four breast biopsy markers in an agarose-gel phantom were measured by two readers on images obtained with the following sequences: T2-weighted fast spin-echo short inversion time fat-suppressed inversion-recovery with magnitude reconstruction (T2-TIRM); T1-weighted spoiled gradient-echo with fat suppression (T1_FL3D), routinely used for dynamic contrast-enhanced imaging; diffusion-weighted imaging (DWI), including a readout segmented echo-planar imaging (RESOLVE-DWI) and echo-planar imaging sequence (EPI-DWI).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!