It is a general principle with arthroplasty insertion that precise implant centering is critical for long term function and outcome. Whilst some authors have proclaimed that lumbar total disc arthroplasty (TDA) may be different, and that off -centre placement may be functionally well tolerated, these claims are premature: significantly worse clinical results have already been reported with poorly placed TDA at 2 years. Accurate TDA placement requires a precise and consistent definition of the desired coronal midline target (which is currently lacking), as well as a procedural mechanism to optimize placement at that target. We summarize our experience, as well as others', in achieving these two requirements. Long-term outcomes after lumbar TDA insertion should only be compared with results from fusion where TDAs have been implanted accurately.

Download full-text PDF

Source
http://dx.doi.org/10.1615/jlongtermeffmedimplants.v18.i4.40DOI Listing

Publication Analysis

Top Keywords

lumbar total
8
total disc
8
disc arthroplasty
8
coronal midline
8
tda placement
8
tda
5
arthroplasty coronal
4
midline definition
4
definition optimal
4
optimal tda
4

Similar Publications

Lumbar Erector Spinae Plane Block Provides Effective Postoperative Analgesia in Hip Fracture Surgery.

J Coll Physicians Surg Pak

January 2025

Department of Orthopaedics and Traumatology, Faculty of Medicine, Sakarya University, Sakarya, Turkiye.

Objective: To compare the postoperative analgesic effectiveness of ultrasound-guided lumbar erector spinae plane (LESP) block with lumbar plexus block (LPB) in patients operated for proximal femur fractures.

Study Design: A randomised controlled trial. Place and Duration of the Study: Sakarya Training and Research Hospital Operation Theatre, Sakarya, Turkiye, between January and June 2023.

View Article and Find Full Text PDF

Surgery is often the treatment of choice for lumbar disc herniation (LDH) with severe leg pain. This study aimed to investigate the efficacy of Condoliase chemonucleolysis (CC) in patients who were nonambulatory because of severe leg pain. A total of 58 patients who underwent CC for conservative treatment-resistant LDH were included in this study.

View Article and Find Full Text PDF

Objective: The potential of robot-assisted (RA) single-position (SP) lateral lumbar interbody fusion (LLIF) warrants further investigation. This study aimed to assess the efficacy of RA-SP-LLIF in improving both clinical and radiographic outcomes in patients undergoing lumbar spinal fusion surgery.

Methods: A total of 59 patients underwent either RA-SP-LLIF (n = 31 cases) or traditional LLIF (n = 28 cases).

View Article and Find Full Text PDF

Objective: When creating minimally invasive spine fusion constructs, accurate pedicle screw fixation is essential for biomechanical strength and avoiding complications arising from delicate surrounding structures. As research continues to analyze how to improve accuracy, long-term patient outcomes based on screw accuracy remain understudied. The objective of this study was to analyze long-term patient outcomes based on screw accuracy.

View Article and Find Full Text PDF

Objective: CSF leaks are a significant source of patient morbidity following intradural spine surgeries. Watertight dural closure is crucial during these procedures to minimize the risk of a CSF leak. This study reports postoperative outcomes and changes in patient management after switching to penetrating titanium clips for dural closure in a large cohort of pediatric patients receiving a tethered cord release (TCR) or a selective dorsal rhizotomy (SDR).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!