Percutaneous screw fixation of acetabular fractures with 2D fluoroscopy-based computerized navigation.

Arch Orthop Trauma Surg

Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital, Jiaotong University, 600 Yishan Road, Shanghai, People's Republic of China.

Published: September 2010

AI Article Synopsis

  • The study evaluated a new technique for treating acetabular fractures using two-dimensional fluoroscopy-based navigation for percutaneous screw fixation, focusing on early treatment results and complications.
  • Eighteen adults (12 with non-displaced and 8 with displaced fractures) were treated with an average surgery time of 24.6 minutes, showing effective screw placement with minimal deviation.
  • Results indicated a significant reduction in displacement after surgery, with most patients experiencing less than 5 mm of gap and step displacements postoperatively, highlighting the technique's potential for improved outcomes.

Article Abstract

Introduction: The treatment of displaced acetabular fractures with formal open reduction and internal fixation has gained general acceptance. However, extensile exposure can lead to complications. Two-dimensional fluoroscopy-based computerized navigation for placement of percutaneous screw across non-displaced acetabular fractures has attracted interest by making use of stored patient-specific imaging data to provide real-time guidance in multiple image planes during implant placement. The purpose of the present study was to document early treatment results and complications associated with this new technique and evaluate its clinical application to displaced acetabular fractures amenable to closed or limited open reduction.

Materials And Methods: Eighteen adult patients with 12 non-displaced and 8 displaced acetabular fractures were treated with percutaneous screw fixation under the guidance of a fluoroscopy-based navigation system. There were 14 men and four women with a mean age of 42.1 years (range 19-54 years). According to the AO and Orthopaedic Trauma Association Classification, there were nine 62-A3, five 62-B1, three 62-B2, and three 62-B3. The mean follow-up was 21 months (range 12-28 months). The mean time from injury to surgery was 4 days (range 2-7 days).

Results: A total of 30 acetabular screws were inserted, including 21 anterior column screws and 9 posterior column screws. The average operation time was 24.6 min (range 16-47 min) from the image acquisition to wound closure. The average fluoroscopic time was 28.4 s (range 11-58 s). Compared to the final position of the screw, the average deviated distance of wire tip was 2.5 mm (range 1.1-3.6 mm) and the average trajectory difference was 2.45 degrees (range 1.5 degrees -4.6 degrees ). Maximal gap displacement averaged 10 mm (range 2-22 mm) preoperatively and 3 mm (range 0-5 mm) postoperatively; while maximal step displacement averaged 4 mm (range 1-10 mm) preoperatively and 2 mm (range 0-4 mm) postoperatively. One patient sustained a transient femoral nerve palsy and resolved 2 months after the operation. No superficial or deep infection occurred. Using the rating system of D'Aubigne and Postel, 13 patients had excellent results, 4 patients had good results, and 1 patient had a fair result.

Conclusion: Percutaneous screw fixation of acetabular fractures with 2D fluoroscopy-based navigation could be applied not only to non-displaced fractures but also to displaced fractures amenable to closed or limited open reduction.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00402-010-1095-2DOI Listing

Publication Analysis

Top Keywords

acetabular fractures
24
percutaneous screw
16
screw fixation
12
displaced acetabular
12
range
11
fixation acetabular
8
fractures
8
fractures fluoroscopy-based
8
fluoroscopy-based computerized
8
computerized navigation
8

Similar Publications

Acetabular fractures are rare fractures of the pelvis which usually result from trauma. Whilst data are reported on sexual and genitourinary function in those with pelvic fractures, less is known about those with isolated acetabulum fractures. This systematic review aimed to determine, first, the frequency of sexual and genitourinary dysfunction following isolated acetabulum fractures and, second, the nature of these complications.

View Article and Find Full Text PDF

Objectives: The 22-modifier in the Current Procedural Terminology (CPT) system indicates increased surgical procedure complexity, aiming to secure greater reimbursement for surgeons. This study investigated the 22-modifier on reimbursement amounts after acetabular fracture fixation.

Methods: Design: Retrospective cohort study.

View Article and Find Full Text PDF

Objectives: To report the frequency of patients with pre- and post-reduction computed tomography (CT) scans associated with acetabular fracture-dislocations and the change of associated intra-articular fragments occurring with joint reduction.

Methods: Design: Retrospective case series.

Setting: Regional Level 1 trauma center.

View Article and Find Full Text PDF

Adequate intraoperative visualization is mandatory for implant application in pelvic ring injuries. Several fluoroscopic X-ray views are in practical use. The gold standard primary X-ray is the anteroposterior view of the pelvis.

View Article and Find Full Text PDF

Introduction And Importance: Neglected posterior hip dislocations in adults are rare, particularly when untreated for years. In developing nations, patients often rely on traditional bone setters, leading to delayed diagnosis and increased complications. Adult hip dislocations carry a higher risk of avascular necrosis and require complex treatments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!