Background/aim: In cases of blurred optic media the ultrasound diagnostics offers useful data about eventual presence of intraocular foreign body as well as about its precise localization in the eye. The aim of this study was to retrospectively analyze echographic findings in patients with the diagnosis of intraocular foreign body with a special interest in localizations of a intraocular foreign body in the eye and the presence of an eventual infection - endophthalmitis. The aim of this study was also to confirm the localization of intraocular foreign body by echography and to test the precision of this method.

Methods: We performed analysis of all cases that had been referred to the ultrasound diagnostices, in which the presence of intraocular foreign body had been confirmed in the period of one year. All examinations were done with B-scan and were confirmed during the surgery - vitrectomy.

Results: In the one-year period we were contacted by 27 patients with intraocular foreign body. In one injured eye the intraocular foreign body was in the lens (3.70%), in 10 injured eyes (37.03%) intraocular foreign body was in the vitreal body. In 15 patients (55.5%) intraocular foreign body was fixed in the retina. In one patient (3.70%) there was a perforating injury, intraocular foreign body was found in the retrobulbar part of the orbit. In 7 injured eyes (25.9%), with the presence of intraocular foreign body, we found signs of endophthalmitis (organized blurring in vitreal space, thickened choroid). Other accompanying echographic findings were: blood in vitreal space, haemophthalmus in 12 cases (44.4%), retinal detachment in 5 cases (18.5%) and subretinal hemorrhagies in 4 cases (14.8%).

Conclusion: Ultrasound diagnostics can very precisely show the localization of intraocular foreign body in the eye that is very important in the choice of approach and timing of surgical treatment. Also the echographic diagnostics may find an accompanying endophthalmitis in the posterior segment of the eye, that is very important for an urgent therapeutic approach.

Download full-text PDF

Source
http://dx.doi.org/10.2298/vsp1003213sDOI Listing

Publication Analysis

Top Keywords

intraocular foreign
52
foreign body
52
body
14
intraocular
13
foreign
13
localization intraocular
12
presence intraocular
12
ultrasound diagnostics
8
aim study
8
echographic findings
8

Similar Publications

Purpose Of The Review: In recent years, Berger's space (BS), the potential space between the posterior lens capsule and the anterior hyaloid membrane, has received little attention from the ophthalmic clinical community. This is primarily due to the limited documentation, with only a few isolated case reports detailing foreign bodies in this area.

Recent Findings: Recent advances in medical imaging technology have enabled the visualization of the BS under various circumstances.

View Article and Find Full Text PDF

We present the case of a patient who came to the emergency department with a significant decrease in vision and dilated pupil in the left eye. Since neurological pathologies were primarily considered, diffusion brain magnetic resonance imaging (MRI) and brain computed tomography (CT) were requested. After the results were reported as normal, we were consulted.

View Article and Find Full Text PDF

Objective: To evaluate systemic inflammatory markers in cases of exogenous endophthalmitis caused by metal foreign bodies after penetrating eye injury and identify risk factors for poor control post-initial emergency surgery.

Methods: Twenty-nine patients with exogenous endophthalmitis underwent emergency surgery with vitrectomy at Xiamen Eye Center (2016-2024). Evaluations included systemic inflammatory markers, microbiology, clinical presentation, treatment strategies, complications, prognostic factors, and visual outcomes.

View Article and Find Full Text PDF

Aim: To assess the utility and efficiency of endoscopy-assisted vitrectomy (EAV) for the treatment of corneal opacity in severe ocular trauma.

Methods: Patients who underwent fundus examination using a preoperative slit lamp and intraoperative endoscopy, followed by EAV and additional surgery were retrospectively recruited. Silicone oil removal and penetrating keratoplasty were used in selected eyes at postoperative follow-ups.

View Article and Find Full Text PDF

Purpose: This study aimed to determine the rate of retained metallic intraocular foreign bodies (IOFBs) following torsional phacoemulsification cataract surgery by an experienced surgeon and elucidate related surgical factors, particle origin theories from existing literature, and postoperative visual impact.

Methods: An observational study was conducted on 300 consecutive cases of cataract who underwent torsional phacoemulsification by a single surgeon using two-handed stop-and-chop technique. The incidence of retained IOFBs was observed and correlated with the surgical parameters and the density of cataract.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!