Objective: The authors report their experience in the treatment of the diaphyseal tibial fractures, using the unilateral radiolucent External Fixator (EF) XCaliber.

Design: A total of 100 patients (average age 35 years, range 16-76) with 103 displaced diaphyseal tibial fractures were treated with the XCaliber. There were 59 type A fractures, 35 type B, and 9 type C (according to the AO classification) and 35 were open fractures.

Main Outcome Measurements: During the last assessment, patients were evaluated for level of pain, ability to perform weight-bearing activities, and number of residual deformities.

Results: The average follow-up time was 24 months, 3 patients (4 fractures) were excluded for final assessment and 1 patient moved abroad. Of the remaining 98 fractures, 83 (84.7%) healed with a single operation in a mean 21 weeks (SD 3.97; 12-38 weeks), 10 fractures had a delayed union and 5 fractures proceeded to a non-union. There were 13 complications. Among them, a loss of reduction was observed in 3 cases due to overload of the EF, in 3 cases, deep pin track infections were observed and 2 fractures healed with more than 1 cm of shortening.

Conclusions: The results are encouraging, since both complex and open fractures were included in this study. The XCaliber was shown to be a valid unilateral external fixator, combining the advantage of radiolucency during application and radioscopic follow-up with a stable and flexible fracture fixation. This represents the first report in the literature specifically examining treatment of tibial diaphyseal fractures with a radiolucent external fixator.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00402-010-1090-7DOI Listing

Publication Analysis

Top Keywords

external fixator
16
fractures
11
103 displaced
8
tibial diaphyseal
8
diaphyseal fractures
8
fractures radiolucent
8
unilateral external
8
diaphyseal tibial
8
tibial fractures
8
radiolucent external
8

Similar Publications

Objective: Investigating the clinical efficacy of treating dorsally displaced distal radial double-column Die-punch fractures using a dorsal approach external fixator combined with Kirschner wires.

Methods: Retrospectively analyzed the clinical data of 15 patients with distal radial double-column Die-punch fractures treated with an external fixator combined with Kirschner wire between July 2020 and January 2023. There were 10 males and 5 females;6 cases on the left side and 9 on the right;age ranged from 22 to 76 years old.

View Article and Find Full Text PDF

Objective: Meta-analysis of the clinical efficacy of plate and external fixator fixation in the treatment of AO-C type distal radius fractures.

Methods: PubMed, Embase, Cochrane Medical Library, Web of Science, CNKI, Wanfang, VIP and SinoMed databases were searched for all literature on randomized controlled clinical trials of AO-C distal radius fractures. The search time limits were from each database.

View Article and Find Full Text PDF

Objective: To investigate the short-term clinical effect of closed reduction single arm external fixator combined with percutaneous needle fixation in the treatment of C1 distal radius fracture in elderly patients.

Methods: Between December 2022 and December 2023, a total of 60 elderly patients diagnosed with type C1 distal radius fractures were treated, comprising 9 males and 51 females. The age ranged from 65 to 84 years old, with an average of (72.

View Article and Find Full Text PDF

Objective: To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).

Methods: Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.

View Article and Find Full Text PDF

Objective: To describe the characteristics of short arm deformity in patients with achondroplasia, and summarize the progress of its lenthening and reconstruction, so as to provide reference for clinical diagnosis and treatment.

Methods: The literature on the lenthening of upper limb with achondroplastic short arm deformity at home and abroad in recent years was reviewed, and the characteristics, extension methods, postoperative management, effectiveness evaluation, and related complications of short arm deformity were summarized.

Results: Achondroplastic short arm deformity affect the patient's daily perineal hygiene activities.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!