Background: A concern regarding the use of metal-on-metal bearings in hip arthroplasty has been that the high levels of metal ions that are released overwhelm the renal threshold for metal excretion, leading to systemic buildup of metals. The purpose of this investigation was to determine if the physiological renal capacity for cobalt clearance and cobalt concentrating efficiency is overwhelmed by the elevation in metal ion levels seen in patients with metal-on-metal-bearing hip devices.
Methods: Concurrent specimens of urine and plasma were obtained from a group of 461 patients (346 men and 115 women) at various intervals after either a unilateral (296) or a bilateral (130) metal-on-metal hip arthroplasty or preoperatively (thirty-five patients; the control specimens). Metal ion analyses were performed with high-resolution inductively coupled mass spectrometry. Renal efficiency was measured as the ratio of urine cobalt concentration to plasma cobalt concentration. Cobalt clearance was calculated by dividing the urine cobalt output in twenty-four hours by the plasma cobalt concentration. Dividing the quotient by 1440 adjusts it to clearance per minute.
Results: The median renal efficiency was found to be 0.9 in the analysis of the preoperative specimens, indicating that there was renal conservation of cobalt. In patients with metal-on-metal bearings, the median renal efficiency was 3.2, indicating that, as a result of cobalt excretion, the cobalt concentration in urine was threefold higher than the concentration in plasma. Linear regression analysis showed that renal efficiency progressively increased at a rate of 9% for every microg/24 hr increase in cobalt release. Cobalt clearance showed a similar trend, increasing from 1.3 mL/min in the preoperative group to 3.7 mL/min in the follow-up group. In the follow-up group, renal cobalt clearance progressively increased from 1.9 to 7.1 mL/min with increasing daily cobalt output, which indicates that with increasing in vivo metal ion release there was a progressive increase in the rate at which the kidneys cleared the plasma of cobalt.
Conclusions: In subjects with no prosthetic device, the kidneys tend to conserve cobalt in the body. We found that, in patients with a metal-on-metal hip prosthesis, there is a progressive increase in cobalt clearance with increasing in vivo wear at the levels of cobalt release expected in patients with an array of metal-on-metal-bearing total joint arthroplasties. We found no threshold beyond which renal capacity to excrete these ions is overwhelmed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2106/JBJS.H.01821 | DOI Listing |
Arthroplast Today
June 2024
Department of Orthopaedic Surgery, Jewish General Hospital, McGill University, Montreal, Quebec, Canada.
Immunoglobulin A (IgA) nephropathy in the presence of a metal-on-metal (MoM) hip arthroplasty is a rare condition that requires close monitoring. A 61-year-old male with bilateral hip osteoarthritis underwent resurfacing hip arthroplasty with MoM articulating surfaces. Prior to his four-year postoperative visit, the patient was diagnosed with IgA nephropathy.
View Article and Find Full Text PDFBone Jt Open
June 2024
Exeter Hip Group, Exeter Hip Unit, Princess Elizabeth Orthopaedic Centre, Royal Devon University Healthcare NHS Foundation Trust, Exeter, UK.
Aims: In metal-on-metal (MoM) hip arthroplasties and resurfacings, mechanically induced corrosion can lead to elevated serum metal ions, a local inflammatory response, and formation of pseudotumours, ultimately requiring revision. The size and diametral clearance of anatomical (ADM) and modular (MDM) dual-mobility polyethylene bearings match those of Birmingham hip MoM components. If the acetabular component is satisfactorily positioned, well integrated into the bone, and has no surface damage, this presents the opportunity for revision with exchange of the metal head for ADM/MDM polyethylene bearings without removal of the acetabular component.
View Article and Find Full Text PDFAm J Cardiol
August 2024
Mount Sinai Fuster Heart Hospital, Icahn School of Medicine at Mount Sinai, New York, New York. Electronic address:
J Nanobiotechnology
June 2024
Lishui Central Hospital and the Fifth Affiliated Hospital of Wenzhou Medical University, Lishui, 323000, P. R. China.
J Biomed Mater Res A
June 2024
Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials (Ministry of Education), School of Materials Science and Engineering, Shandong University, Jinan, Shandong, China.
Acellular porcine cornea (APC) has been used in corneal transplantation and treatment of the corneal diseases. Sterilization is a key step before the application of graft, and irradiation is one of the most commonly used methods. In this paper, APC was prepared by the physical freeze-thawing combined with biological enzymes, and the effects of the electron beam (E-beam) and cobalt 60 (Co-γ) at the dose of 15 kGy on the physicochemical properties, structure, immunogenicity, and biocompatibility of the APC were investigated.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!