A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Liquid chromatographic determination of endogenous phytohormones in vegetable samples based on chemical derivatization with 6-oxy(acetylpiperazine) fluorescein. | LitMetric

Liquid chromatographic determination of endogenous phytohormones in vegetable samples based on chemical derivatization with 6-oxy(acetylpiperazine) fluorescein.

J Agric Food Chem

Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072, China.

Published: April 2010

In phytohormone analysis, mass spectrometry (MS)-based methods are primary and powerful tools. However, complex sample preparation and high cost are problems for their application. As a complement for MS-based methods, a new fluorescent labeling reagent for carboxylic acids, 6-oxy(acetylpiperazine) fluorescein (APF), has been used for the determination of endogenous phytohormones, including indolebutyric acid, 1-naphthaleneacetic acid and 2,4-dichlorophenoxyacetic acid. The derivatization yield was maximized by optimizing derivatization conditions in detail, and the derivatives of three phytohormones could be separated completely in 15 min on a C18 column with fluorescence detection at lambda(ex)/lambda(em) = 467/512 nm. The derivatization limits could reach 0.1 microM, and the detection limits (signal-to-noise ratio = 3) were 4.43-14.2 nM. The proposed method has been applied to the determination of the exogenous phytohormones in the crude extracts of vegetable samples without extra purification and enrichment with recoveries of 94.2-102.4%.

Download full-text PDF

Source
http://dx.doi.org/10.1021/jf100581uDOI Listing

Publication Analysis

Top Keywords

determination endogenous
8
endogenous phytohormones
8
vegetable samples
8
6-oxyacetylpiperazine fluorescein
8
ms-based methods
8
liquid chromatographic
4
chromatographic determination
4
phytohormones
4
phytohormones vegetable
4
samples based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!