Layered materials which can be easily cleaved have proved to be excellent samples for the study of atomic scale friction. The layered transition metal dichalcogenides have been particularly popular. These materials exhibit a number of interesting properties ranging from superconductivity to low frictional coefficients. In this paper we have investigated the tribology of the dichalcogenide-WTe2. The coefficient of friction is less than 0.040 along the Te rows and increases to over 0.045 across the rows. The frictional forces almost doubled at normal loads of 5000 nN when scanning in the [010] direction in comparison to the [100] direction. The frictional responses of the AFM probe have been monitored in the frictional force and force-versus-distance (f-d) mode. A comparison between the outcomes using the two different modes demonstrates the factors which need to be considered for accurate measurements.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1166/jnn.2010.1400 | DOI Listing |
Chem Asian J
January 2025
Indian Institute of Science Education and Research Bhopa;, Chemistry, IISER Bhopal, Chemistry, #229,, Academic Building #2, Bhopal bypass road, Bhauri, 462066, Bhopal, INDIA.
Polymerases erroneously incorporate Guanine-Thymine (dG•dT) mismatches in genomic DNA that further evades repair by transient sampling of tautomeric/ionic states compromising fidelity of repairing dG•dT mismatches. In conjunction, significant frequency of ribose (mis)incorporation in duplex DNA permits for misincorporated-mismatch in the genome. Ribose incorporated G(rG) mismatched with T(rG•dT) is the most stable across all misincorporated-mismatch calling into question the conformational consequences of the ribose sugar in addition to the mismatch.
View Article and Find Full Text PDFAdv Mater
January 2025
Department of Physics, University of Ulsan, Ulsan, 44619, South Korea.
Efficient magnetization control is a central issue in magnetism and spintronics. Particularly, there are increasing demands for manipulation of magnetic states in van der Waals (vdW) magnets with unconventional functionalities. However, the electrically induced phase transition between ferromagnetic-to-antiferromagnetic states without external magnetic field is yet to be demonstrated.
View Article and Find Full Text PDFJ Phys Chem Lett
January 2025
Department of Physics, Chalmers University of Technology, 412 96 Göteborg, Sweden.
Functional gold nanoparticles have emerged as a cornerstone in targeted drug delivery, imaging, and biosensing. Their stability, distribution, and overall performance in biological systems are largely determined by their interactions with molecules in biological fluids as well as the biomolecular layers they acquire in complex environments. However, real-time tracking of how biomolecules attach to colloidal nanoparticles, a critical aspect for optimizing nanoparticle function, has proven to be experimentally challenging.
View Article and Find Full Text PDFPhys Chem Chem Phys
January 2025
School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu 611731, Sichuan, China.
The structural stability of the energetic material 2,2',4,4',6,6'-hexanitrostilbene (-HNS) under high pressure is critical for optimizing its detonation performance and low sensitivity. However, its structural response to external pressure has not been sufficiently investigated. In this study, high-pressure single-crystal X-ray diffraction data of -HNS demonstrate that the sample exhibits pronounced anisotropic strain, demonstrating an unusual negative linear compressibility (NLC) along the axis, with a coefficient of -4.
View Article and Find Full Text PDFMagn Reson Imaging
January 2025
Institute of Fluid Mechanics, University of Rostock, Rostock, Germany.
Purpose: To improve the current method for MRI turbulence quantification which is the intravoxel phase dispersion (IVPD) method. Turbulence is commonly characterized by the Reynolds stress tensor (RST) which describes the velocity covariance matrix. A major source for systematic errors in MRI is the sequence's sensitivity to the variance of the derivatives of velocity, such as the acceleration variance, which can lead to a substantial measurement bias.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!