Objective: To compare the efficacy of universal gloving with emollient-impregnated gloves with standard contact precautions for the control of multidrug-resistant organisms (MDROs) and to measure the effect on healthcare workers' (HCWs') hand skin health.

Design: Prospective before-after trial.

Setting: An 18-bed surgical intensive care unit.

Methods: During phase 1 (September 2007 through March 2008) standard contact precautions were used. During phase 2 (March 2008 through September 2008) universal gloving with emollient-impregnated gloves was used, and no contact precautions. Patients were screened for vancomycin-resistant Enterococcus (VRE) and methicillin-resistant Staphylococcus aureus (MRSA). HCW hand hygiene compliance and hand skin health and microbial contamination were assessed. The incidences of device-associated infection and Clostridium difficile infection (CDI) were determined.

Results: The rate of compliance with contact precautions (phase 1) was 67%, and the rate of compliance with universal gloving (phase 2) was 78% (P = .01). Hand hygiene compliance was higher during phase 2 than during phase 1 (before patient care, 40% vs 35% of encounters; P = .001; after patient care, 63% vs 51% of encounters; P < .001). No difference was observed in MDRO acquisition. During phases 1 and 2, incidences of device-related infections, in number of infections per 1,000 device-days, were, respectively, 3.7 and 2.6 for bloodstream infection (P = .10), 8.9 and 7.8 for urinary tract infection (P = .10), and 1.0 and 1.1 for ventilator-associated pneumonia (P = .09). The CDI incidence in phase 1 and in phase 2 was, respectively, 2.0 and 1.4 cases per 1,000 patient-days (P = .53). During phase 1, 29% of HCW hand cultures were MRSA positive, compared with 13% during phase 2 (P = .17); during phase 1, 2% of hand cultures were VRE positive, compared with 0 during phase 2 (P = .16). Hand skin health improved during phase 2.

Conclusions: Compared with contact precautions, universal gloving with emollient-impregnated gloves was associated with improved hand hygiene compliance and skin health. No statistically significant change in the rates of device-associated infection, CDI, or patient MDRO acquisition was observed. Universal gloving may be an alternative to contact precautions.

Download full-text PDF

Source
http://dx.doi.org/10.1086/651671DOI Listing

Publication Analysis

Top Keywords

universal gloving
24
contact precautions
24
gloving emollient-impregnated
16
emollient-impregnated gloves
16
skin health
16
phase
13
hand skin
12
hand hygiene
12
hygiene compliance
12
phase phase
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!