Surface arthroplasty simulations were generated using 3-dimensional computed tomographic scans from 61 consecutive patients presenting with idiopathic osteoarthritis to evaluate the change in femoral component positioning that would allow optimal alignment when resurfacing a cam-type deformity. Anatomical parameters were measured to quantify the influence of the deformity on the insertion technique of the femoral implant. A modified femoral head ratio was initially calculated from plain radiographs to define the severity of cam deformity in these patients. A severe deformity required more superior translation of the entry point and greater reaming depth to allow safe insertion with optimal implant alignment. This could be achieved while preserving the leg length, minimizing the component size, and maximizing the amount of host bone contact, although the horizontal femoral offset was reduced. These findings suggest that the femoral component can be safely inserted by modifying the surgical technique despite progressive deformity of the femoral head.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2010.01.100DOI Listing

Publication Analysis

Top Keywords

femoral component
12
cam deformity
8
deformity insertion
8
femoral head
8
femoral
7
deformity
5
insertion femoral
4
component
4
component hip
4
hip resurfacing
4

Similar Publications

A 52-year-old man with a short chronic total occlusion in the left superficial femoral artery underwent drug-coated balloon (DCB) angioplasty. Evaluation using integrated backscatter intravascular ultrasound revealed that the plaque volume of fibrosis was compressed just after treatment (from 494.67 mm to 398.

View Article and Find Full Text PDF

Can robotic arm-assisted total knee arthroplasty be applied to valgus deformity.

Arch Orthop Trauma Surg

January 2025

Department of Orthopaedic Surgery, University Hospital centre (Saint Etienne), Avenue Albert Raimond, Saint-priest-en-Jarez, 42270, France.

Introduction: Total knee arthroplasty (TKA) in valgus knees is challenging. Optimal ligament balance, implant neutral or moderate valgus alignment are crucial but conventional instrumentations usually lead to outliers. Robotic arm assisted TKA (RATKA) advantages could answer this challenge.

View Article and Find Full Text PDF

Background: The ideal anteversion at which the acetabular and femoral components for a total hip arthroplasty (THA) should be implanted is still a subject of debate. One alignment philosophy being explored is restoration of individual constitutional femoral and acetabular anteversion. This study aimed to measure combined anteversion in a healthy hip population and understand the expected phenotypes and ranges for constitutional hip alignment.

View Article and Find Full Text PDF

Polyetheretherketone (PEEK) is a high-performance polymer material for developing varying orthopedic, spine, cranial, maxillofacial, and dental implants. Despite their commendable mechanical properties and biocompatibility, the major limitation of PEEK implants is their low affinity to osseointegrate with the neighboring bone. Over the last two decades, several efforts have been made to incorporate bioactive components such as bioceramic particles in PEEK to enhance its osseointegration capacity.

View Article and Find Full Text PDF

In functionally aligned total knee arthroplasty, femoral component rotation follows the transepicondylar axis to achieve flexion balance.

Knee Surg Sports Traumatol Arthrosc

January 2025

Clinical Research Department, Sydney Knee Specialists, Kogarah, New South Wales, Australia.

Purpose: In functionally aligned (FA) total knee arthroplasty (TKA), femoral component rotation (FCR) is personalised to optimise flexion gap balance. As axial malalignment has been attributed to patellofemoral complications, this study assessed FA FCR in relation to the surgical transepicondylar axis (TEA) and early implant survivorship.

Methods: We analysed 446 robotic-assisted primary TKAs in 393 patients using FA with preresection gap balancing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!