Background/aim: This study aimed to determine the effect of nonsteroidal anti-inflammatory drugs (NSAIDs) on the results of rapid urease test (RUT).

Patients And Methods: The study evaluated 210 consecutive patients for the diagnosis of Helicobacter pylori (H. pylori) infection. They were divided into case and control groups based on history of NSAID use (n=70 each). Two biopsy specimens were collected from antrum and corpus of stomach during endoscopy and sent for rapid urease testing and histopathology. Sensitivity, specificity, and accuracy rate of RUT test were compared against histology.

Results: The average age was 55.2+/-12.9 and 43.3+/-12.1 years in the case and control groups, respectively. Among NSAID users, RUT sensitivity, specificity and accuracy rate were all 100%. The sensitivity, specificity and accuracy rate of RUT in patients without history of NSAID use were 97.37, 98.57 and 98.14%, respectively. The overall sensitivity, specificity and accuracy rate of RUT were 98.57, 99.29, and 99.04%, respectively.

Conclusion: Our study shows that sensitivity, specificity and accuracy rate of RUT are not affected by NSAID use. Rapid urease test remains a reliable test for diagnosis of H. pylori in patients on NSAIDs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3016498PMC
http://dx.doi.org/10.4103/1319-3767.61238DOI Listing

Publication Analysis

Top Keywords

sensitivity specificity
20
specificity accuracy
20
accuracy rate
20
rapid urease
16
rate rut
16
urease test
12
helicobacter pylori
8
pylori infection
8
patients nsaids
8
case control
8

Similar Publications

Background: Monitoring vital signs in hospitalized patients is crucial for evaluating their clinical condition. While early warning scores like the modified early warning score (MEWS) are typically calculated 3 to 4 times daily through spot checks, they might not promptly identify early deterioration. Leveraging technologies that provide continuous monitoring of vital signs, combined with an early warning system, has the potential to identify clinical deterioration sooner.

View Article and Find Full Text PDF

Contrast-enhanced mammography (CEM) is growing in clinical use due to its increased sensitivity and specificity compared to full-field digital mammography (FFDM) and/or digital breast tomosynthesis (DBT), particularly in patients with dense breasts. To perform an intraindividual comparison of MGD between FFDM, DBT, a combination protocol using both FFDM and DBT (combined FFDM-DBT), and CEM, in patients undergoing breast cancer screening. This retrospective study included 389 women (median age, 57.

View Article and Find Full Text PDF

Background: An accurate knowledge of a patient's risk of cord-level intraoperative neuromonitoring (IONM) data loss is important for an informed decision-making process prior to deformity correction, but no prediction tool currently exists.

Methods: A total of 1,106 patients with spinal deformity and 205 perioperative variables were included. A stepwise machine-learning (ML) approach using random forest (RF) analysis and multivariable logistic regression was performed.

View Article and Find Full Text PDF

Background: Blood loss during liver transplantation (LT) remains a major concern associated with increased morbidity and reduced patient and graft survival. The high complexity of the procedure associated with the multifaceted origin of the bleeding urges early identification of high-risk patients and proper monitoring of hemostasis disorders in order to improve results. The accuracy of international normalized ratio (INR) and activated partial thromboplastin time (aPTT) to evaluate coagulation status in cirrhotic patients has been doubted.

View Article and Find Full Text PDF

We developed a reversed-phased high-performance liquid chromatographic method combining ultraviolet detection and integrated pulsed amperometric detection for the simultaneous quantification of dopamine, 5-hydroxyindolacetic acid, homovanillic acid, serotonin, 3,4-dihydroxyphenylacetic acid, norepinephrine and epinephrine. All target components were completely separated in a C18 column with isocratic elution of 5% acetonitrile solution containing 8 mM HClO4 and 0.20 mM 1-octanesulfonic acid as an ion pairing reagent.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!