Background: Various surgical techniques have been proposed to treat small aortic annulus. We have used small-diameter mechanical valves for small aortic annulus. The present study examined aortic valve replacement with small diameter mechanical valves to determine their effectiveness.
Methods: The study included 67 patients who underwent elective, isolated aortic valve replacement with ATS-Advanced Performance (AP) valves (ATS Medical, Inc, Minneapolis, MN) within our department. The patients were divided into two groups; patients receiving the 16-mm AP valve (16-mm group) and those receiving valves 18-mm AP or larger (>16-mm group).
Results: The mean age of the 16-mm group was significantly higher than that of the >16-mm group. Body surface area was significantly smaller in the 16-mm group than the >16-mm group. We found no significant differences in preoperative conditions between the groups. The effective orifice area index of the mechanical valve was lower in the 16-mm group (0.87+/-0.06 vs 1.12+/-0.13 cm2/m2, p<0.0001). Six patients (40%) in the 16-mm group fell into the category of prosthesis-patient mismatch cases. Although the postoperative pressure gradient was higher in the 16-mm group (33.7+/-12.5 vs 23.16+/-8.78, p<0.01), left ventricular mass index and left ventricular ejection fraction at early and at late follow-up improved from the preoperative period in both groups. We found no significant differences in incidence of postoperative complications, including death.
Conclusions: We believe aortic valve replacement with small-diameter mechanical valves (the ATS-AP valves) in patients with a small annulus provides satisfactory remote prognosis. The use of mechanical valves in elderly patients is considered acceptable with strict clinical monitoring to prevent thromboembolism and anticoagulation therapy-induced complications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.athoracsur.2009.12.074 | DOI Listing |
Int J Biol Macromol
January 2025
Materials Engineering Group, Golpayegan College of Engineering, Isfahan University of Technology, Golpayegan 87717-67498, Iran.
3D printing, as a layer-by-layer manufacturing technique, enables the customization of tissue engineering scaffolds. Surface modification of biomaterials is a beneficial approach to enhance the interaction with living cells and tissues. In this research, a polylactic acid/polyethylene glycol scaffold containing 30 % bredigite nanoparticles (PLA/PEG/B) was fabricated utilizing fused deposition modeling (FDM) 3D printing.
View Article and Find Full Text PDFJ Arrhythm
February 2025
Department of Cardiology Institute of Medicine, University of Tsukuba Tsukuba Japan.
Background/objectives: Very high-power and short-duration (vHPSD) ablation with QDOT MICRO™ facilitates speedy and safe ablation for pulmonary vein isolation. A brief time interval between ablating two neighboring sites with vHPSD may potentially influence the size and geometry of the lesions. This study evaluates lesion formation when delivering adjacent applications using vHPSD at various inter-lesion times (ILTs).
View Article and Find Full Text PDFJ Dent Sci
December 2024
Faculty of Dentistry, Department of Oral and Maxillofacial Surgery, Chulalongkorn University, Bangkok, Thailand.
Background/purpose: Many designs of static computer-assisted implant surgery (sCAIS) are available for clinician to achieve proper implant position. However, there were not any studies that approached the design alone to evaluate whether sleeve-in-sleeve or sleeve-on-drill design provided most accuracy implant position. The purpose of this study was to investigate the precision of implant placement with sleeve-in-sleeve and sleeve-on-drill static computer assisted implant surgery (sCAIS) designs.
View Article and Find Full Text PDFBackground: Acromegaly, although rare, is associated with multiple manifestations and complications; its high morbidity and mortality makes it a challenge. Treatment involves surgery and pharmacological therapies, focusing on biochemical normalization. This study analyzes the biochemical control in Colombian patients with acromegaly, seeking to improve the understanding of the effects of treatments in the management of the disease.
View Article and Find Full Text PDFJ Optom
January 2025
Department of Ophthalmology, Peking University People's Hospital, Beijing, China; Eye Diseases and Optometry Institute, Beijing, China; Beijing Key Laboratory of Diagnosis and Therapy of Retinal and Choroid Diseases, Beijing, China; College of Optometry, Peking University Health Science Center, Beijing, China.
Purposes: To investigate the 12-month effectiveness of Diverse Segmented Defocus Optics (DSDO) and Defocus Incorporated Multiple Segments (DIMS) spectacle lenses in a real-world clinical population in myopic and pre-myopic Chinese children.
Methods: About 364 subjects prescribed DSDO or DIMS were enrolled. Axial length (AL) and cycloplegic spherical equivalent refraction (SER) changes over 12 months were measured.