Objective: To detail the principles of using model-based determination of regional myocardial blood flow (MBF) by computed tomography (CT) and demonstrate its in vivo applicability.

Methods: Dual-source CT was performed with a dynamic protocol comprising acquisition with alternating table positions in ECG-triggered end-systolic timing every second for 30 s. The results of two reconstructions were merged into one final image stack (coverage 73 mm), with low spatial frequency components from a 360 degrees reconstruction and high spatial frequency components from a dual-source cardiac partial image reconstruction. A parametric deconvolution technique was used to fit the time-attenuation curves (TAC), the maximum slope of which was used to derive MBF.

Results: One study participant underwent dynamic myocardial stress perfusion imaging (9.6 mSv) followed by invasive coronary angiography and measurement of fractional flow reserve as the gold standard. MBF was 159 ml/100 ml/min in the non-ischaemic anterolateral and 86 ml/100 ml/min in the inferoseptal ischaemic wall.

Conclusion: This first evaluation indicates that mathematical modelling of voxel TACs can potentially be used to quantify differences in MBF in a clinical setting. If confirmed in feasibility studies, cardiac CT may allow for parallel assessment of morphology and haemodynamic relevance of coronary artery disease.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-010-1715-9DOI Listing

Publication Analysis

Top Keywords

dynamic myocardial
8
myocardial stress
8
stress perfusion
8
perfusion imaging
8
alternating table
8
table positions
8
spatial frequency
8
frequency components
8
ml/100 ml/min
8
imaging fast
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!