Purpose: To retrospectively assess the rate of detection of skull fractures at cranial computed tomography (CT) achieved with the use of curved maximum intensity projections (MIPs) compared with that achieved by reading transverse sections only.

Materials And Methods: The institutional review board approved this research and waived informed consent. A curved thin (3-mm) MIP of the skull cap and a curved thick (50-mm) MIP of the skull base were obtained from the cranial CT data in 200 consecutive patients with head trauma. Four radiologists (two residents without experience in cranial CT and two consultants) independently evaluated all cases. Each radiologist reported findings in 100 patients by using transverse sections only and findings in the other 100 patients by using the unfolded view. The radiologists were blinded to patient names, and patient and group orders were randomized. The results were compared with a standard of reference established by two experts from all prior reading results, all reconstructions, and high-spatial-resolution multiplanar reformats. Logistic regression with repeated measurements was used for statistical analysis.

Results: The experts found 63 fractures in 30 patients. When transverse sections only were used, the mean patient-based fracture detection rate was 43% (13 of 30) for inexperienced and 70% (21 of 30) for experienced readers; with curved MIPs, the rates were 80% (24 of 30) and 87% (26 of 30), respectively. Overall sensitivity was higher with curved MIPs (P < .001); specificity was higher with transverse sections (P < .001).

Conclusion: Curved MIPs enable a significantly higher fracture detection rate than transverse sections. They also considerably close the experience gap in fracture detection rate between residents and experts.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.10091096DOI Listing

Publication Analysis

Top Keywords

transverse sections
20
fracture detection
12
detection rate
12
curved mips
12
detection skull
8
skull fractures
8
mip skull
8
findings 100
8
100 patients
8
patients transverse
8

Similar Publications

The incidence of Popeye Deformity after Soft Tissue Biceps Tenodesis is Comparable to Biceps Anchor Tenodesis and Lower than Biceps Tenotomy During Arthroscopic Rotator Cuff Repair- letter to editor.

Arthroscopy

January 2025

Department of Orthopedic Surgery, National Defense Medical Center, Tri-Service General Hospital, #325, Section 2, Chenggung Road, Neihu 114, Taipei, Taiwan; Department of Orthopedic Surgery, Keelung Branch of Tri-Service General Hospital, Taiwan. Electronic address:

We have carefully reviewed the article entitled "The incidence of Popeye Deformity after Soft Tissue Biceps Tenodesis is Comparable to Biceps Anchor Tenodesis and Lower than Biceps Tenotomy During Arthroscopic Rotator Cuff Repair" by Hyun Gon Kim et al. and found it very interesting. While we appreciate the authors' efforts, we have some questions about certain aspects of the study methodology that we hope they can address.

View Article and Find Full Text PDF

Advancing Hydrogel-Based 3D Cell Culture Systems: Histological Image Analysis and AI-Driven Filament Characterization.

Biomedicines

January 2025

Embrapa Genetic Resources and Biotechnology, Laboratory of Nanobiotechnology (LNANO), Brasília 70770-917, DF, Brazil.

Machine learning is used to analyze images by training algorithms on data to recognize patterns and identify objects, with applications in various fields, such as medicine, security, and automation. Meanwhile, histological cross-sections, whether longitudinal or transverse, expose layers of tissues or tissue mimetics, which provide crucial information for microscopic analysis. : This study aimed to employ the Google platform "Teachable Machine" to apply artificial intelligence (AI) in the interpretation of histological cross-section images of hydrogel filaments.

View Article and Find Full Text PDF

To explore the changes of atlantoaxial joint spaces and pharyngeal airway after combined orthodontic-orthognathic treatment in skeletal class Ⅲ patients with mandibular deviation. A total of 34 adult skeletal class Ⅲ patients (10 males and 24 females) with mandibular deviation who received combined orthodontic-orthognathic treatment at the Department of Orthodontics and the Department of Orthognathic Surgery in the Stomatological Hospital of Chongqing Medical University from August 2014 to October 2021 were retrospectively selected. The patients were 22 (5) years old (18-33 years).

View Article and Find Full Text PDF

This study investigates the quasi-static and dynamic compression performance of a newly designed stacked pyramidal lattice (SPL) structure composed of struts that resemble I-beams. These novel lattice structures are 3D-printed considering three different stacking sequences, and their stiffness, strength, and energy absorption properties are experimentally assessed through low-velocity impact (1.54 m/s) and quasi-static compression tests.

View Article and Find Full Text PDF

Characterization of hydrodynamics around plates shaped like dragonfly wings as a sediment reduction measure in a sewer system.

Water Res

January 2025

School of Water Conservancy and Transportation, Zhengzhou University, Zhengzhou, China; Yellow River Laboratory, Zhengzhou University, Zhengzhou, China.

Sediment control is a major concern in sewer management. Early studies focused on the parameters affecting the efficiency of existing dredging facilities, and novel long-term sediment reduction measures have not been developed. Superior sediment reduction performance has been demonstrated for plates folded at 25° placed in a pipe.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!