Multi-stage cascade impactors (CIs) are the preferred measurement technique for characterizing the aerodynamic particle size distribution of an inhalable aerosol. Stage mensuration is the recommended pharmacopeial method for monitoring CI "fitness for purpose" within a GxP environment. The Impactor Sub-Team of the European Pharmaceutical Aerosol Group has undertaken an inter-laboratory study to assess both the precision and accuracy of a range of makes and models of instruments currently used for optical inspection of impactor stages. Measurement of two Andersen 8-stage 'non-viable' cascade impactor "reference" stages that were representative of jet sizes for this instrument type (stages 2 and 7) confirmed that all instruments evaluated were capable of reproducible jet measurement, with the overall capability being within the current pharmacopeial stage specifications for both stages. In the assessment of absolute accuracy, small, but consistent differences (ca. 0.6% of the certified value) observed between 'dots' and 'spots' of a calibrated chromium-plated reticule were observed, most likely the result of treatment of partially lit pixels along the circumference of this calibration standard. Measurements of three certified ring gauges, the smallest having a nominal diameter of 1.0 mm, were consistent with the observation where treatment of partially illuminated pixels at the periphery of the projected image can result in undersizing. However, the bias was less than 1% of the certified diameter. The optical inspection instruments evaluated are fully capable of confirming cascade impactor suitability in accordance with pharmacopeial practice.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2850462 | PMC |
http://dx.doi.org/10.1208/s12249-010-9405-0 | DOI Listing |
ACS Omega
December 2024
Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH) Centers for Disease Control and Prevention (CDC),1090 Tusculum Ave,Cincinnati, Ohio 45226, United States.
Inhalation exposure to respirable crystalline silica (RCS) during the fabrication of engineered stone-based kitchen countertops has been on the rise in recent years and has become a significant occupational health problem in the United States and globally. Little is known about the presence of nanocrystalline silica (NCS), i.e.
View Article and Find Full Text PDFSci Total Environ
December 2024
Department of Civil and Environmental Engineering, Universidad del Norte, Barranquilla, Colombia. Electronic address:
This study assessed the prevalence and spatial distribution of viable ultrafine and fine antibiotic-resistant bacteria aerosols (ARB) in the Metropolitan Area of Barranquilla, Colombia, pre- and post-lockdown (September 2019 to December 2020). Samples were systematically collected from urban, suburban, and rural sites using a six-stage viable cascade impactor. We employed logistic regression and Bayesian Neural Network Classifiers to analyze meteorological variables' influence on antibiotic resistance persistence.
View Article and Find Full Text PDFAnal Chem
December 2024
Department of Environmental Engineering, Eskişehir Technical University, Eskişehir 26555, Türkiye.
Inhalable micro(nano)plastics (MNPs) have emerged as a significant global concern due to their abundance and persistence in the atmosphere. Despite a growing body of literature addressing the analytical requirements of airborne MNPs, the issue of inhalable fractions and analysis of slotted substrates remains unclear. Therefore, the objective of this study is to perform a systematic particle-based analysis and characterization of inhalable microplastics (MPs) collected by a high-volume sampler equipped with a five-stage cascade impactor with a size range of 10 μm to <0.
View Article and Find Full Text PDFNature
December 2024
Max-Planck-Institut für Astronomie, Heidelberg, Germany.
Asteroid discoveries are essential for planetary-defense efforts aiming to prevent impacts with Earth, including the more frequent megaton explosions from decameter impactors. While large asteroids (≥100 km) have remained in the main belt since their formation, small asteroids are commonly transported to the near-Earth object (NEO) population. However, due to the lack of direct observational constraints, their size-frequency distribution -which informs our understanding of the NEOs and the delivery of meteorite samples to Earth-varies significantly among models.
View Article and Find Full Text PDFEur J Pharm Biopharm
November 2024
School of Pharmacy, Faculty of Health & Medical Sciences, Taylor's University, Subang Jaya, Malaysia; Digital Health and Medical Advancements Impact Lab, Taylor's University, Subang Jaya, Malaysia.
Zerumbone (ZER), a compound derived from the rhizome of Zingiber Zerumbet (L.) Smith, has demonstrated anti-inflammatory properties but suffers from poor water solubility, limiting its clinical application. While ZER's effects on lung inflammation are known, its role in lung fibrosis remains unexplored.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!