Off-pump correction of coronary fistula: the single suture technique approach.

Rev Bras Cir Cardiovasc

Cardiopatias Cirúrgicas Valvares, Av. Dr. Enéas de Carvalho Aguiar, 44, São Paulo, SP, Brasil.

Published: July 2010

The single suture technique was developed to obtain stabilization and exposure of all all coronary branches during off-pump coronary artery bypass, while maintaining hemodynamic stabilily during the procedure. We describe the use of this technique during an off-pump correction of a coronary artery fistula associated with right coronary dilatation. The suggested technique is quicker and less complex than on-pump surgery. Furthermore, it can be a useful tool for congenital fistula correction in select cases, stimulating the practice of less invasive heart surgery in these patients.

Download full-text PDF

Source
http://dx.doi.org/10.1590/s0102-76382009000500023DOI Listing

Publication Analysis

Top Keywords

off-pump correction
8
correction coronary
8
single suture
8
suture technique
8
coronary artery
8
coronary
5
coronary fistula
4
fistula single
4
technique
4
technique approach
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!