Molecular dynamics simulations of matrix-assisted laser desorption/ionization were carried out to investigate laser pulse width and fluence effects on primary and secondary ionization process. At the same fluence, short (35 or 350 ps) pulses lead to much higher initial pressures and ion concentrations than longer ones (3 ns), but these differences do not persist because the system relaxes toward local thermal equilibrium on a nanosecond timescale. Higher fluences accentuate the initial disparities, but downstream differences are not substantial. Axial velocities of ions and neutrals are found to span a wide range, and be fluence dependent. Total ion yield is only weakly dependent on pulse width, and consistent with experimental estimates. Secondary reactions of matrix cations with analyte neutrals are efficient even though analyte ions are ablated in clusters of matrix.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jms.1732DOI Listing

Publication Analysis

Top Keywords

pulse width
12
molecular dynamics
8
dynamics simulations
8
simulations maldi
4
maldi laser
4
fluence
4
laser fluence
4
fluence pulse
4
width dependence
4
dependence plume
4

Similar Publications

Background: Accurate prediction for survival in individualized patients with cardiac resynchronization therapy with a defibrillator (CRT-D) is difficult.

Methods: We analyzed the New Japan cardiac device treatment registry (JCDTR) database to develop a survival prediction model for CRT-D recipients.

Results: Four hundred and eighty-two CRT-D recipients, at the implantation year 2018-2021, with a QRS width ≥120 ms and left ventricular ejection fraction (LVEF) ≤35% at baseline, were analyzed.

View Article and Find Full Text PDF

This article presents an innovative asymmetric multilevel inverter (MLI) topology that outperforms conventional counterparts. The introduced topology presents a breakthrough in implementing power electronics control by maximizing specific levels while minimizing switching components. A cutting-edge control scheme for optimal operation of the cascaded half-bridge MLI is presented.

View Article and Find Full Text PDF

Based on the symmetric initiation mechanism of double-wing cracks in coal rock mass induced by high-pressure electro-recoil water pressure, fracturing experiments have been performed on coal rock mass under different water pressures and discharge conditions using high-voltage electric pulse hydraulic fracturing devices. Combined with CT scans, the crack spatial distribution inside the post-break coal rock mass was analyzed and found that the edge of the water injection hole is prone to produce double-wing cracks along the drilling hole diameter. ABAQUS is used to verify the physical test and extend the test conditions, the geometric parameter change, morphological expansion rule and crack initiation mechanism of double-wing crack in coal rock mass under different discharge conditions and ground stress conditions are studied.

View Article and Find Full Text PDF

NMR spectroscopy presents boundless opportunities for understanding the structure, dynamics, and function for a broad range of scientific applications. Solid-state NMR (SSNMR), in particular, provides novel insights into biological and material systems that are not amenable to other approaches. However, a major bottleneck is the extent of user training and the difficulty of obtaining reproducible, high-quality experimental results, especially for the sophisticated multidimensional pulse sequences that are essential to provide site-resolved measurements in large biomolecules.

View Article and Find Full Text PDF

Recent progress in digital microfluidics has revealed the distinct advantages of liquid marbles, such as minimal surface friction, reduced evaporation rates, and non-wettability compared to uncoated droplets. This study provides a comprehensive examination of an innovative technique for the precise, contamination-free manipulation of non-magnetic water liquid marbles (WLMs) carried by a ferrofluid liquid marble (FLM) under the control of direct current (DC) and pulse-width modulation (PWM) magnetic fields. The concept relies on the phenomenon in which an FLM and WLMs form a shared meniscus when placed together on a water surface, causing the WLMs to closely track the magnetically actuated FLM.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!