Background And Objectives: Initial experience with transcatheter closure of patent ductus arteriosus (PDA) using detachable coils and Amplatzer duct occluder devices is reported. We evaluated the outcome, complications, and influence of the learning curve, and also assessed the need of surgical backup for such interventional procedures.

Methods: From January 2000 to December 2004, 121 patients underwent transcatheter closure of PDA. Aortic angiogram was performed to evaluate the size, position, and shape of the duct for appropriately choosing the occluder device type and size. A second aortic angiogram was performed 10 minutes after device deployment. Echocardiography was repeated at intervals of 24 hours, then at 1, 3, and 6 months after the procedure to assess complications. Stepwise multiple regression analysis was used to assess the role of experience in improving the outcome of the procedure.

Results: Of 121 cases, four patients had pulmonary artery embolization of the occluder device which was successfully retrieved in the catheterization laboratory, while two others had embolization that required surgical intervention. Four patients had temporary residual leak, nine had protrusion of the device into the aorta without significant Doppler pressure gradient or hemolysis on follow-up, and five had partial hemodynamically insignificant obstruction to the left pulmonary artery. Statistical analysis showed that the effect of the learning curve and experience was responsible for 93% improvement in the procedural outcome over the five-year study period.

Conclusion: Transcatheter occlusion of PDA is safe and effective alternative to surgery. Complications occurred in those with unfavorable duct anatomy and with the use of multiple coils. Surgical backup was important for such interventional procedures. Experience played a major role in the proper choice of device type and size which greatly influenced the outcome of the procedure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2840760PMC
http://dx.doi.org/10.4103/0974-2069.52804DOI Listing

Publication Analysis

Top Keywords

transcatheter closure
12
learning curve
12
closure patent
8
patent ductus
8
ductus arteriosus
8
surgical backup
8
backup interventional
8
aortic angiogram
8
angiogram performed
8
occluder device
8

Similar Publications

Arrhythmias Following Patent Foramen Ovale Closure: An Unsolved Enigma.

Life (Basel)

December 2024

First Department of Cardiology, Hippokration Hospital, Athens Medical School, National and Kapodistrian University of Athens, Vas. Sofias 114, 11527 Athens, Greece.

Patent foramen ovale (PFO) closure has proven to be an effective method of reducing the risk of recurrent stroke in patients with embolic stroke of unknown origin (ESUS). One of the most recognized post-procedural complications is the de novo occurrence of supraventricular arrhythmias, mainly atrial fibrillation, in the first three months following PFO closure. Earlier studies reported the incidence to be around 3.

View Article and Find Full Text PDF

Background: Vascular and bleeding complications remain a concern after transfemoral transcatheter aortic valve replacement (TAVR). The impact of the sheath type on these complications remains unclear.

Methods: The prospective MARVEL registry study analyzed enrolled 500 patients undergoing large-bore transfemoral procedures and arteriotomy closure with the MANTA vascular closure device from 10 hospitals in Europe and Canada.

View Article and Find Full Text PDF

Aortic annular rupture is a rare and usually fatal complication of TAVR. We report the case of a sub-annular aortic rupture contained in the right ventricle and percutaneously repaired. The procedure was complicated by new-onset severe tricuspid regurgitation related to tricuspid injury during wire externalization and immediately treated by transcatheter edge-to-edge repair.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!