A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cyclam-based "clickates": homogeneous and heterogeneous fluorescent sensors for Zn(II). | LitMetric

Cyclam-based "clickates": homogeneous and heterogeneous fluorescent sensors for Zn(II).

Inorg Chem

The Joseph Priestly Building, School of Biological and Chemical Sciences, Queen Mary University of London, Mile End Road, London, E1 4NS, UK.

Published: April 2010

In an effort to improve upon the recently reported cyclam based zinc sensor 1, the "click"-generated 1,8-disubstituted analogue 2 has been prepared. The ligand shows a 2-fold increase in its fluorescence emission compared to 1 exclusively in the presence of Zn(II) that is typical of switch-on PET fluorescent sensors. Single crystal X-ray diffraction of complexes of model ligand 10 reveals that the configuration adopted by the macrocyclic framework is extremely sensitive to the metal ion to which it coordinates. For Zn(II), Mg(II), and Li(I) the metal ions adopt an octahedral geometry with a trans III configuration of the cyclam ring. In contrast for Ni(II) the ligand adopts the rare cis V configuration, while for Cu(II) a clear preference for five-coordinate geometry is displayed with a trans I configuration of the macrocyclic ring being observed in two essentially isostructural compounds prepared via different routes. The ligand displays an increased selectivity for Zn(II) compared to 1 in the majority of cases with excellent selectivity upheld over Na(I), Mg(II), Ca(II), Mn(II), Ni(II), Co(II), and Fe(III). In contrast for Cu(II) and Hg(II) little improvement was observed for 2 compared to 1 and for Cd(II) the selectivity of the new ligand was inferior. In the light of these findings and the slower response times for ligand 2, our original "click"-generated cyclam sensor system 1 was employed in a proof of concept study to prepare a heterogeneous sol-gel based material which retains its PET response to Zn(II). The versatile nature of the sol-gel process importantly allows the simple preparation of a variety of nanostructured materials displaying high surface area-volume ratio using fabrication methods such as soft lithography, electrospinning, and nanopipetting.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ic901939xDOI Listing

Publication Analysis

Top Keywords

fluorescent sensors
8
ligand
6
znii
5
cyclam-based "clickates"
4
"clickates" homogeneous
4
homogeneous heterogeneous
4
heterogeneous fluorescent
4
sensors znii
4
znii effort
4
effort improve
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!