Objectives: Diagnosis of low-grade chondrosarcoma, especially discrimination between enchondroma and low-grade chondrosarcoma, may be difficult pathologically. The aim of this study was to evaluate the value of thallium-201 (Tl-201) scintigraphy in the diagnosis of chondrosarcoma and to investigate whether there was a correlation between Tl-201 uptake and tumor grade.
Methods: We retrospectively evaluated 121 patients with pathologically proven bone and soft tissue tumors diagnosed between the years 1999 and 2007. All patients were followed by the Bone and Soft Tissue Tumor Working Group in our hospital. Twenty-three patients, mean age 44 +/- 15 (range 17-72) years, with a diagnosis of cartilaginous tumors were included. Increased Tl-201 uptake at the lesion sites greater than background was evaluated as malignant tumor. For the pathologic classification, a grading system (grade 1-3) based on the histopathologic findings was used. Pearson correlation coefficient was used to determine whether there was any correlation between Tl-201 uptake and tumor grade in chondrosarcoma.
Results: There were 7 enchondromas and 16 chondrosarcomas. Four of 16 patients with chondrosarcoma had lesions pathologically classified as grade 3, 5 as grade 2, and 7 had grade 1 chondrosarcoma. Increased Tl-201 uptake was observed in all patients with grade 3 chondrosarcoma and 2 patients with grade 2 chondrosarcoma. Of 10 patients with chondrosarcoma, 3 grade 2 chondrosarcomas and 7 grade 1 chondrosarcomas, there was no Tl-201 uptake in the tumor region. A significant correlation was found between Tl-201 uptake and tumor grade in chondrosarcoma (p = 0.002, r = 0.71). Only a few reports in literature have demonstrated false negative results in low-grade chondrosarcoma.
Conclusion: Tl-201 uptake was related to tumor grade in chondrosarcoma. If there is a possibility of chondrosarcoma, Tl-201 scintigraphy should be reported with caution.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s12149-010-0361-2 | DOI Listing |
Curr Opin Cardiol
September 2019
Division of Cardiology, Cook County Health.
Purpose Of Review: The assessment of myocardial viability continues to be a pressing and sometimes challenging clinical question. Among other imaging modalities proven to be useful in the assessment of myocardial viability, single-photon emission computed tomography (SPECT) instrumentation and expertise continue to be the most widely available to the practicing physicians. Understanding the utility of SPECT myocardial perfusion imaging in this domain is an enduring need.
View Article and Find Full Text PDFJ Nucl Cardiol
February 2020
Departments of Imaging and Medicine and Biomedical Sciences, Cedars-Sinai Medical Center, and the Cedars-Sinai Heart Institute, 8700 Beverly Boulevard, Los Angeles, CA, 90048, USA.
Introduction: Assessment of myocardial uptake of Tc-99m-pyrophosphate (Tc-99m PYP) is pivotal in distinguishing transthyretin-associated cardiac amyloidosis (ATTR) from light chain amyloid (AL). It is often difficult to differentiate myocardial uptake from blood pool radioactivity with planar imaging or SPECT. We studied whether simultaneous dual-isotope Tc-99m PYP/Tl-201 SPECT improves assessment of Tc-99m PYP uptake compared to single-isotope SPECT.
View Article and Find Full Text PDFJ Nucl Cardiol
December 2018
CHRU-Nancy, Université de Lorraine, Department of Nuclear Medicine, 54000, Nancy, France.
Purpose Of The Report: This study aimed at assessing an original low-dose dual-isotope procedure in which the abnormal stress Tc-99m Sestamibi SPECT is followed by rest Tl-201 SPECT, along with a head-to-head comparison with a single-isotope procedure.
Methods And Results: One hundred two patients, referred for a low-dose stress-SPECT with Sestamibi (123 ± 20 MBq) on a CZT camera and for whom a rest Sestamibi SPECT was warranted, had an additional Tl-201 rest-SPECT (52 ± 5 MBq) between stress and rest Sestamibi SPECT recordings. Tl-201 images were processed for spill-over and scatter corrections, and uptake differences with stress Sestamibi SPECT were analyzed: (1) for rest acquisitions from Tl-201 (dual-isotope procedure) and from Sestamibi (single-isotope procedure) and (2) in segments for which a diagnosis of ischemia, infarct, or normal perfusion was achieved.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!