Background: The aim of this study was to evaluate the incidence of posterior capsule opacification up to 50 months following 1.7-mm bimanual MICS-cataract surgery.
Methods: Bimanual MICS cataract surgery was performed in 197 eyes (135 patients) via two 1.7-mm corneal incisions. Four MICS acrylic foldable IOLs were implanted: AcriSmart 48S-5, n = 54 (Acritec GmbH, Hennigsdorf, now AT.Smart 48S Carl-Zeiss-Meditec, AG, Jena, Germany), ThinLens UltraChoice 1.0, n = 53 (Technomed GmbH, Baesweiler, Germany), AcriFlex 46, n = 41 und AcriFlex 48 CSE, n = 7 (Acrimed GmbH, Berlin, now: Lentis L-303, Oculentis GmbH, Berlin, Germany) and CareFlex, n = 43 (w2o Medizintechnik AG, Bruchsal, Germany). Statistical analysis was performed using the Kaplan-Meier technique.
Results: High levels of completeness of follow-up rates were: ThinLens 96%, CareFlex 100%, AcriSmart 93%, AcriFlex 92%. The capsulotomy rate was 43.13% for ThinLens within a mean/max. follow-up period of 801/1131 days, 34.88% for CareFlex (565/872 days), 40% for AcriSmart (988/1506 days) and 15.91% for AcriFlex (728/975 days). By limiting the follow-up period to a comparable maximum of 850 days for all four IOLs, our capsulotomy rates were as follows: ThinLens 33.33%, CareFlex 32.56 %, AcriSmart 20.0% and AcriFlex 11.36%. MICS IOLs have higher capsulotomy rates than hydrophobic acrylic lenses and sharp-edged silicone lenses. In literature comparisons MICS-IOLs do not exceed the variance levels of capsulotomy rates of PMMA, hydrophilic acrylic and silicone lenses without sharp edges. Cases of decentration or luxation of MICS-IOLs following Neodym:YAG laser capsulotomy were not detected. Capsulotomy frequency with the CareFlex was statistically significantly higher in comparison to the AcriSmart (Log Rank Mantel Cox Test, p = 0.007) and AcriFlex (log rank Mantel Cox test, p = 0.002).
Conclusions: Capsulotomy rates observed varied for the four MICS-IOL-types tested. The posterior capsule opacification frequency of the two best MICS-IOLs (AcriFlex, AcriSmart) did not exceed the higher variance levels of posterior capsule opacification rates of the round-edged "conventional" non-MICS IOLs of PMMA, silicone or hydrophilic acryl material. Sharp-edged silicone or hydrophobic acrylic "conventional" lenses have shown lower posterior capsule opacification rates.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1055/s-0028-1109853 | DOI Listing |
Am J Ophthalmol Case Rep
December 2024
Capital Health, Trenton, NJ, USA.
Optic capture of a three-piece lens in the absence of posterior capsule support is an effective strategy for stabilizing and sequestering the optic to reduce the risk of dislocation and UGH syndrome compared to sulcus placement. We present a novel technique that facilitates optic capture in the presence of a contracted, fibrotic rhexis opening, while minimizing stress on the zonules by using iris retractors to assist in stabilization and expansion of the rhexis, followed by direct injection of the optic of the lens behind the anterior capsule opening into an optic captured configuration.
View Article and Find Full Text PDFJ Orthop Case Rep
January 2025
Department of Orthopaedics, University of Toledo Medical Center, Ohio, USA.
Introduction: Bony and ligamentous ankle injuries are some of the most commonly treated injuries by orthopedic surgeons. Open ligamentous ankle injuries without an associated fracture or dislocation are rare and to our knowledge have only sparsely been described in the literature. We present a case and successful treatment of an open lateral ankle injury with capsular rupture and ligamentous damage without fracture or dislocation in a 22-year-old female.
View Article and Find Full Text PDFDiagnostics (Basel)
January 2025
Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Bei-Hu Branch, Taipei 10845, Taiwan.
A 66-year-old woman presented with persistent knee effusion three months after undergoing a cemented medial uni-compartmental knee replacement. She was afebrile and able to walk with a stick. Physical examination revealed moderate effusion.
View Article and Find Full Text PDFRetina
October 2024
Department of Ophthalmology, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China.
Purpose: The research investigates the efficacy of hydroxypropyl methylcellulose (HPMC) treatment in facilitating the development of compact water droplets on the rear surface of synthetic lenses with capsule imperfections during the process of fluid-air exchange.
Method: This study examined four patients with intraocular lens (IOL) implants and posterior capsule defects who experienced the formation of dense water droplets on the posterior surface following fluid-air exchange. When this occurrence obstructs fundus visualization during surgery, it is recommended to suspend the surgical procedure.
Clin Kidney J
January 2025
Healthy Aging Research Center, Chang Gung University, Taoyuan City, Taiwan.
Background: Damage to brain white matter often occurs in individuals with chronic kidney disease, which might be related to their cognitive decline. This study aims to investigate tract-specific white matter damage in patients with end-stage kidney disease by using fixel-based analysis.
Methods: Images of 31 end-stage kidney disease patients and 16 normal controls (aged: 61.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!