Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The primary purpose of this study was to evaluate the ability of a home device preferential hyperacuity perimeter to discriminate between patients with choroidal neovascularization (CNV) and intermediate age-related macular degeneration (AMD), and the secondary purpose was to investigate the dependence of sensitivity on lesion characteristics.
Methods: All participants were tested with the home device in an unsupervised mode. The first part of this work was retrospective using tests performed by patients with intermediate AMD and newly diagnosed CNV. In the second part, the classifier was prospectively challenged with tests performed by patients with intermediate AMD and newly diagnosed CNV. The dependence of sensitivity on lesion characteristics was estimated with tests performed by patients with CNV of both parts.
Results: In 66 eyes with CNV and 65 eyes with intermediate AMD, both sensitivity and specificity were 0.85. In the retrospective part (34 CNV and 43 intermediate AMD), sensitivity and specificity were 0.85 +/- 0.12 (95% confidence interval) and 0.84 +/- 0.11 (95% confidence interval), respectively. In the prospective part (32 CNV and 22 intermediate AMD), sensitivity and specificity were 0.84 +/- 0.13 (95% confidence interval) and 0.86 +/- 0.14 (95% confidence interval), respectively. Chi-square analysis showed no dependence of sensitivity on type (P = 0.44), location (P = 0.243), or size (P = 0.73) of the CNV lesions.
Conclusion: A home device preferential hyperacuity perimeter has good sensitivity and specificity in discriminating between patients with newly diagnosed CNV and intermediate AMD. Sensitivity is not dependent on lesion characteristics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/IAE.0b013e3181d1a75e | DOI Listing |