A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Modified poly-L-lactic acid injection technique: safety and efficacy of "cross-fanning" in non-HIV-related facial atrophy. | LitMetric

Proper injection of poly-l-lactic acid has a role in avoiding development of subcutaneous papules. We evaluated the safety and efficacy of our injection technique ("cross-fanning") and compared it to 4 previous studies. Forty patients were evaluated for adverse events (bruising, edema, erythema, subcutaneous papules) and satisfaction. Papule incidence was compared with the other studies. The incidence of papules (4/40) was significantly lower than that of VEGA and Chelsea and Westminster (P = 0.00003, P = 0.03), but not significantly different than APEX002 or Blue Pacific (P = 0.42, P = 0.61). Bruising (5/40), edema (2/40), papules (4/40), and patient self-satisfaction (80%, P = 0.0001) was also documented. We maintain that cross-fanning has an excellent safety profile and patient satisfaction rate. We also maintain that our modified technique has advantages over the recommended "tunneling cross-hatch" and "depot" technique. Because 38 of 40 patients were HIV-negative, this study also represents the first single-practice series of proper injection of poly-l-lactic acid administration in the immuno-competent patient.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SAP.0b013e3181b143d2DOI Listing

Publication Analysis

Top Keywords

poly-l-lactic acid
12
injection technique
8
safety efficacy
8
proper injection
8
injection poly-l-lactic
8
subcutaneous papules
8
papules 4/40
8
modified poly-l-lactic
4
injection
4
acid injection
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!