Performance of laser fluorescence at tooth surface and histological section.

Lasers Med Sci

Department of Pediatric and Community Dentistry, Dental School, Philipps-University of Marburg, Georg-Voigt-Str. 3, 35033, Marburg, Germany.

Published: March 2011

This study aimed to evaluate a laser fluorescence device (the DIAGNOdent) and a visual classification system (ICDAS-II) for occlusal caries diagnosis. It also aimed to determine whether fluorescence measurements taken at the tooth surface correlate with the fluorescence measurements taken within the body of the lesion. The occlusal surfaces of 100 extracted permanent teeth were examined using ICDAS-II and DIAGNOdent (LF-tooth). Serial sections were made and lesion depth was assessed histologically. DIAGNOdent readings were also taken from the sections (LF-section). There were significant positive strong correlations between ICDAS-II and histology (r(S) = 0.71) and LF-section and histology (r(S) = 0.70), and only moderate correlations between LF-tooth and histology (r(S) = 0.51) and LF-tooth and LF-section (r(S) = 0.60). Diagnostic accuracy for ICDAS-II was generally better than for LF-tooth. While the DIAGNOdent device provides an objective reading for detection and monitoring of carious lesions, using the cut-off ranges previously suggested leads to inferior performance.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10103-010-0768-yDOI Listing

Publication Analysis

Top Keywords

laser fluorescence
8
tooth surface
8
fluorescence measurements
8
performance laser
4
fluorescence
4
fluorescence tooth
4
surface histological
4
histological study
4
study aimed
4
aimed evaluate
4

Similar Publications

Altered DNA dynamics at lesion sites are implicated in how DNA repair proteins sense damage within genomic DNA. Using laser temperature-jump (T-jump) spectroscopy combined with cytosine-analog Förster Resonance Energy Transfer (FRET) probes that sense local DNA conformations, we measured the intrinsic dynamics of DNA containing 3 base-pair mismatches recognized in vitro by Rad4 (yeast ortholog of XPC). Rad4/XPC recognizes diverse lesions from environmental mutagens and initiates nucleotide excision repair.

View Article and Find Full Text PDF

Objective: Ex vivo confocal laser scanning microscopy (EVCM) is an emerging imaging technique, which offers rapid tissue examination. While the current literature shows promising results in the evaluation of non-melanoma skin cancer, only limited research exists on the application of EVCM in melanocytic lesions. This study aimed to assess the utility of EVCM in the characterization of melanocytic lesions and compare its findings with gold-standard histopathology.

View Article and Find Full Text PDF

LuAlO:Ce Fluorescent Ceramic with Deep Traps: Thermoluminescence and Photostimulable Luminescence Properties.

Materials (Basel)

December 2024

Engineering Research Center of Optical Instrument and System, Ministry of Education and Shanghai Key Lab of Modern Optical System, University of Shanghai for Science and Technology, No. 516 Jungong Road, Shanghai 200093, China.

Electron-trapping materials have attracted a lot of attention in the field of optical data storage. However, the lack of suitable trap levels has hindered its development and application in the field of optical data storage. Herein, LuAlO:Ce fluorescent ceramics were developed as the optical storage medium, and high-temperature vacuum sintering induced the formation of deep traps (1.

View Article and Find Full Text PDF

Macrophage (Mph) polarization and functional activity play an important role in the development of inflammatory lung conditions. The previously widely used bimodal classification of Mph into M1 and M2 does not adequately reflect the full range of changes in polarization and functional diversity observed in Mph in response to various stimuli and disease states. Here, we have developed a model for the direct assessment of Mph from bronchial alveolar lavage fluid (BALF) functional alterations, in terms of phagocytosis activity, depending on external stimuli, such as exposure to a range of bacteria (, and ).

View Article and Find Full Text PDF

Study Objective: We present the results of the first feasibility and safety study of a novel multi-modality falloposcope, in 19 volunteers. The falloposcope incorporated multispectral fluorescence imaging (MFI) and optical coherence tomography (OCT) for evaluation of the fallopian tubes (FT).

Methods: Nineteen females undergoing elective salpingectomy were recruited in this IRB-approved study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!