The effect of femoral component rotation on the extensor retinaculum of the knee.

J Orthop Res

Orthopaedic Surgery Department, Newcastle University Hospital, Newcastle upon Tyne NE2 4HH, United Kingdom.

Published: September 2010

Malrotation of the femoral component may cause patellofemoral complications after total knee replacement (TKR). We hypothesized that femoral component malrotation would cause excessive lengthening of the retinacula. Retinacular length changes were measured by threading fine sutures along them and attaching these to the patella and to displacement transducers. The knee post-TKR was flexed-extended while the quadriceps were tensed, then the measurements repeated after rotating the femoral component 5 degrees internally and then 5 degrees externally. Internal rotation shortened the medial patellofemoral ligament (MPFL) significantly from 100 degrees to 0 degrees extension. External rotation lengthened the MPFL significantly from 90 degrees to 0 degrees extension. The transverse fibers of the lateral retinaculum showed no significant differences. The MPFL attaches directly from bone to bone, so it was lengthened directly by movement of the trochlea and patella, whereas the deep transverse fibers of the lateral retinaculum attach to the mobile iliotibial tract, so they were not lengthened directly.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jor.21117DOI Listing

Publication Analysis

Top Keywords

femoral component
16
degrees degrees
8
degrees extension
8
transverse fibers
8
fibers lateral
8
lateral retinaculum
8
lengthened directly
8
degrees
6
femoral
4
component rotation
4

Similar Publications

Introduction: Numerous orthopaedic procedures including dynamic hip screw plating and various osteotomies require placement of a reference guide pin or K wire to direct bone cuts or for drilling screw holes. Appropriate positioning of these wires is a critical component of surgery. Irrespective of whether one is a seasoned surgeon or an apprentice, these wires often need repositioning and readjustment.

View Article and Find Full Text PDF

Background: Dual mobility (DM) implants in total hip arthroplasty provide excellent range of motion with low dislocation rates. A complication of this design is intraprosthetic dislocation (IPD), where the polyethylene (PE) liner dissociates from the femoral head. In older designs, IPD occurred due to a small head size and late PE wear with head-capture-mechanism failure.

View Article and Find Full Text PDF

Versatility of the Anterolateral Thigh Flap for Abdominal Wall Reconstruction.

Plast Reconstr Surg Glob Open

January 2025

From the Department of Plastic Surgery and Hand Surgery, Cantonal Hospital Aarau, Aarau, Switzerland.

Background: Abdominal wall reconstruction represents an ambitious and demanding challenge. This study aimed to illustrate the versatility of the anterolateral thigh (ALT) flap in its different designs for the reconstruction of complex defects of the abdominal wall.

Methods: Charts of patients with complex abdominal wall defects who underwent a reconstruction with an ALT flap at the University Hospital of Zurich (2018-2020) were reviewed retrospectively.

View Article and Find Full Text PDF

Purpose: >The aim of this multicenter study was to analyze the potential impact of patient demographics and cementation technique towards the development of radiolucent lines (RLLs) in primary total knee arthroplasty (TKA). It was hypothesized that cementation techniques, including higher cement volume, double-layer cementation technique and hardening in full extension, reduce RLL incidence by improving stability, whereas demographic factors such as age, BMI and smoking may increase RLL risk by affecting bone quality and mechanical loading.

Methods: Altogether, 776 patients (median age: 70.

View Article and Find Full Text PDF

Background And Purpose:  Early migration of the uncemented cruciate-sacrificing rotating platform ATTUNE and Low Contact Stress (LCS) tibial components was classified as at-risk for aseptic loosening rates exceeding 6.5% at 15 years based on recent fixation-specific migration thresholds. In this secondary report of a randomized controlled trial (RCT) we aimed to evaluate whether the 5-year migration, inducible displacement, and the clinical outcome of the ATTUNE components were comparable to those of the LCS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!