A head phantom prototype to verify subdural electrode localization tools in epilepsy surgery.

Neuroimage

Institute of Biomedical Engineering, Faculty of Electrical Engineering and Information Technology, Dresden University of Technology, Dresden, Germany.

Published: January 2011

When planning epilepsy surgery, the position of subdural electrodes in relation to the cortex is crucial. Electrodes may dislocate after implantation. Neurosurgeons are highly interested in the accuracy of methods that visualize these electrodes. In order to determine the accuracy of an electrode visualization method, we have developed a physical head phantom and evaluated our new method of subdural electrode localization. This method projects automatically segmented electrodes of a preimplantation computed tomography (CT) data set onto the segmented brain surface of a postimplantation magnetic resonance imaging (MRI) data set within 2 to 5 min. The phantom consists of a skull, an adipose layer for skin replication, and a deformable brain. It further contains gyri and sulci structures, composed of gelatin and different additives used as phantom material for white matter, gray matter, and cerebrospinal fluid. The phantom allows a well-defined displacement of an "implanted" electrode grid perpendicular to the brain surface. By using the phantom data, we demonstrated that our electrode visualization tool did in fact function accurately. The image contrasts between different phantom materials in MRI and CT phantom data sets were similar to patient data sets. The phantom appears suitable for obtaining a more complex patient data replication, as well as for simulating different deformation scenarios.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.neuroimage.2010.03.007DOI Listing

Publication Analysis

Top Keywords

head phantom
8
subdural electrode
8
electrode localization
8
epilepsy surgery
8
electrode visualization
8
phantom
8
data set
8
brain surface
8
phantom data
8
data sets
8

Similar Publications

Significance: In the last years, time-resolved near-infrared spectroscopy (TD-NIRS) has gained increasing interest as a tool for studying tissue spectroscopy with commercial devices. Although it provides much more information than its continuous wave counterpart, accurate models interpreting the measured raw data in real time are still lacking.

Aim: We introduce an analytical model that can be integrated and used in TD-NIRS data processing software and toolkits in real time.

View Article and Find Full Text PDF

Background: Ultrasound education is transitioning from in-person training to remote methods using mixed reality (MR) and 5G networks. Previous studies are mainly experimental, lacking randomized controlled trials in direct training scenarios.

Objective: This study aimed to compare an MR-based telesupervised ultrasound education platform on private 5G networks with traditional in-person training for novice doctors.

View Article and Find Full Text PDF

The application of a virtual rubber dam isolation training system in dental preclinical education.

Heliyon

July 2024

Department of Endodontics, Tianjin Stomatological Hospital, School of Medicine, Nankai University, Tianjin, 300041, China.

Objective: To assess the efficacy of a virtual rubber dam isolation training system in enhancing preclinical dental education.

Methods: A total of 28 Grade 4 undergraduate dental students were randomly divided into two groups: a virtual simulation priority group and a conventional phantom-head priority group. The virtual simulation priority group underwent virtual simulation training initially, followed by conventional phantom-head training.

View Article and Find Full Text PDF

To accurately model and validate the 6 MV Elekta Compactlinear accelerator using the Geant4 Application for Tomographic Emission (GATE). In particular, this study focuses on the precise calibration and validation of critical parameters, including jaw collimator positioning, electron source nominal energy, flattening filter geometry, and electron source spot size, which are often not provided in technical documentation. Methods: Simulation of the Elekta Compact6 MV linear accelerator was performed using the Geant4 Application for Tomographic Emission (GATE) v.

View Article and Find Full Text PDF

Introduction The Synaptive magnetic resonance imaging (MRI) system (Synaptive Medical, Toronto, Canada) is a midfield 0.5 T head-only scanner for imaging the head and neck in adults and pediatrics. The system received US FDA and Health Canada clearance for clinical use in 2020.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!