We present the temperature dependence of absorption and reduced scattering coefficients of 1.8% Intralipid measured by frequency-domain photon-migration spectroscopy between 710 and 850 nm. These measurements were made in the physiologically relevant 30 to 40 degrees C temperature range. The temperature coefficients for absorption were consistent during heating and cooling and follow closely other reported results. The change in absorption coefficient at 740 nm suggests that a minimum temperature change of 4 degrees C is observable within the error limits. We found that the reduced scattering coefficient shows a hysteresis with temperature at 740 nm. The temperature coefficient for reduced scattering determined from heating cycle measurements agrees with theory and other measurements within the error limits.

Download full-text PDF

Source
http://dx.doi.org/10.1117/1.3290820DOI Listing

Publication Analysis

Top Keywords

reduced scattering
12
intralipid measured
8
measured frequency-domain
8
frequency-domain photon-migration
8
photon-migration spectroscopy
8
error limits
8
temperature
6
temperature-dependent optical
4
optical properties
4
properties intralipid
4

Similar Publications

To compare 1D (linear) tumor volume calculations and classification systems with 3D-segmented volumetric analysis (SVA), focusing specifically on their effectiveness in the evaluation and management of NF2-associated vestibular schwannomas (VS). VS were clinically followed every 6 months with cranial, thin-sliced (< 3 mm) MRI. We retrospectively reviewed and used T1-weighted post-contrast enhanced (gadolinium) images for both SVA and linear measurements.

View Article and Find Full Text PDF

A paper-based SERS/colorimetry substrate for reliable detection.

Spectrochim Acta A Mol Biomol Spectrosc

January 2025

State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, PR China. Electronic address:

For on-site analysis, the combination of surface enhanced Raman scattering (SERS) and colorimetry, as a dual-mode detection, can effectively improve the accuracy of detection, and reduce the influence of instrument fluctuation, which greatly improves the accuracy and reliability of the results. However, the preparation of SERS/colorimetry substrates are usually time-consuming and costly, which limits their practical applications. In this paper, a hydrophobic paper-based SERS/colorimetry substrate can be prepared by a simple spraying method.

View Article and Find Full Text PDF

Zeatin Elicits Premature Erythrocyte Senescence Through Calcium and Oxidative Stress Mediated by the NOS/PKC/CK1α Signaling Axis.

Dose Response

January 2025

Department of Clinical Laboratory Sciences, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia.

Cytokinins are plant hormones that regulate cell growth and differentiation. In particular, zeatin (ZTN) delays cellular senescence of human fibroblasts and keratinocytes and exhibits anticancer activity. Chemotherapy-induced anemia is a major side effect of anticancer therapy secondary to premature senescence of red blood cells (RBCs).

View Article and Find Full Text PDF

Activated Graphite with Richly Oxygenated Surface from Spent Lithium-Ion Batteries for Microwave Absorption.

Small

January 2025

School of Materials and Physics & Center of Mineral Resource Waste Recycling, China University of Mining and Technology, Xuzhou, Jiangsu, 221116, China.

Designing spent graphite anodes from lithium-ion batteries (LIBs) for applications beyond regenerated batteries offers significant potential for promoting the recycling of spent LIBs. The battery-grade graphite, characterized by a highly graphitized structure, demonstrates excellent conductive loss capabilities, making it suitable for microwave absorption. During the Li-ion intercalation and deintercalation processes in battery operation, the surface layer of spent graphite (SG) becomes activated, forming oxygen-rich functional groups that enhance the polarization loss mechanism.

View Article and Find Full Text PDF

Linear digital filters are at the core of image reconstruction and processing for many coherent optical imaging techniques, such as digital holography (DH) or optical coherence tomography (OCT). They can also be efficiently implemented using fast Fourier transform (FFT) with appropriate transfer/filter functions that operate in the frequency domain. However, even with optimal filter design, they suffer from side effects such as sidelobe generation or resolution limitations, e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!