The surface soil samples of Fuxin opencast coal overburden dumps were collected in the field and the spectral reflectance and characteristic parameters of the soil samples, such as moisture content, pH, electrical conductivity (EC), available potassium (K+) content, and soil organic matter content (SOM), were measured. The Analysis results indicated that the curves of the soil spectral reflectance decreased with increasing the laid years. The possible reasons were the influences of soil texture and color. Although the valleys of the spectral reflectance appeared at 1 420, 1 910 and 2 210 nm, they were not conspicuous on the lime soil and mixture soil reflectance curves at 1 420 and 2 210 nm. With discussing the spectral reflectance of different types of soil texture, it's easy to find that the reflectance of fine grained soil was higher than the rough grained soil. Correlations between soil spectral reflectance and soil parameters were analyzed. The results showed that there was a positive relation between reflectance and pH, and correlation coefficient decreased with the wavelength increasing. There was no relationship between spectral reflectance and EC, and negative relations were observed between spectral reflectance and soil parameters, K+ and SOM, respectively. A high correlation coefficient was found between spectral reflectance and SOM, and the highest correlation coefficient reached -0. 76. The exponential correlation was found between sol spectral reflectance and soil moisture content to analyze all samples. According to different years and textures, more detail was described about the correlation between spectral reflectance of characteristic wavelength (1 910 and 1 943 nm) and soil moisture content. Meanwhile, the linear correlations were found under different conditions and higher correlation coefficients were obtained. In order to estimate SOM, five wavelengths (1 350, 1 602, 1 862, 2 160 and 2 227 nm) were selected based on principal component analysis to build a multiple linear regression model. The multiple correlation coefficient of calibration model (R2(C)) was 0.737 4, and the multiple correlation coefficient of validation (R2(V)) was 0.682 4. It indicated that the model was able to meet the needs of monitoring SOM in Fuxin opencast coal mine.
Download full-text PDF |
Source |
---|
Brain
January 2025
Department of Neurology, Medical College of Wisconsin, Milwaukee, WI 53226, USA.
Acoustic-phonetic perception refers to the ability to perceive and discriminate between speech sounds. Acquired impairment of acoustic-phonetic perception is known historically as "pure word deafness" and typically follows bilateral lesions of the cortical auditory system. The extent to which this deficit occurs after unilateral left hemisphere damage and the critical left hemisphere areas involved are not well defined.
View Article and Find Full Text PDFAnal Chim Acta
January 2025
Key Laboratory of High Performance Manufacturing for Aero Engine (MIIT), Northwestern Polytechnical University, 127 West Youyi Road, Xi'an, 710072, China. Electronic address:
Background: Fast and accurate classification of steel can effectively improve industrial production efficiency. In recent years, the use of laser-induced breakdown spectroscopy (LIBS) in conjunction with other techniques for material classification has been developing. Plasma Acoustic Emission Signal (PAES) is a type of modal information separate from spectra that is detected using LIBS, and it can reflect some of the sample's physicochemical information.
View Article and Find Full Text PDFChaos
January 2025
School of Mathematics and Statistics, Jiangsu Normal University, Xuzhou 221116, China.
We demonstrate that fundamental nonlinear localized modes can exist in the Chen-Lee-Liu equation modified by several parity-time (PT) symmetric complex potentials. The explicit formula of analytical solitons is derived from the physically interesting Scarf-II potential, and families of spatial solitons in internal modes are numerically captured under the optical lattice potential. By the spectral analysis of linear stability, we observe that these bright solitons can remain stable across a broad scope of potential parameters, despite the breaking of the corresponding linear PT-symmetric phases.
View Article and Find Full Text PDFBackground: Alzheimer's disease is a devastating neurodegenerative disorder with a complex pathogenesis. One main pathological feature utilised in diagnosis is neurodegeneration or neuronal injury, which is reflected in reductions in cerebral glucose metabolism measured by [18F]Fluorodeoxyglucose ([18F]FDG) positron emission tomography (PET). Here we evaluated the involvement of glial reactivity measured with magnetic resonance spectroscopy (MRS) and cerebral blood flow measured with arterial spin labelling (ASL) on [18F]FDG PET as a measure of cerebral glucose metabolism.
View Article and Find Full Text PDFAlzheimers Dement
December 2024
The William H. Annesley, Jr, EyeBrain Center, Farber Neuroscience Institute at Thomas Jefferson University, Philadelphia, PA, USA.
Background: FLIO a novel in vivo reproducible, non-invasive imaging technology, measures fluorescence lifetime decay in two spectral channels for short-lived retinal chromophores in two domains: Channel 1 emission wavelength 498-560 nm corresponding to NADH and FAD/ATP function and Channel 2, 560-720 nm wavelength corresponding to lipofuscin/lysosomal function. These data reflect the retinal mitochondrial molecular environment. Mitochondrial dysfunction has been recently explored as a cause of decreased synaptic function and cognitive decline in AD.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!