The Bt11 maize-specific qualitative detection method based on polymerase chain reaction (PCR) in the JAS analytical test handbook has been widely used for administrative monitoring of GM crops and quality control of commercially distributed grains. In the present investigation, some apparently false-positive detections were observed in assays using the Bt11 maize-specific method, and these erroneous results were proved to have been caused by non-specific DNA amplification. We improved the detection method to reduce non-specific amplification by decreasing the concentration of magnesium ions in the PCR mixture. The subsequent evaluation of analytical performance demonstrated no marked difference between the currently used and the improved methods, except for the reduced non-specific amplification. We conclude that the currently used standard method should be replaced with the improved method for the reliable detection of Bt11 maize.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3358/shokueishi.51.32 | DOI Listing |
Genet Med
January 2025
Newborn Screening Ontario, Children's Hospital of Eastern Ontario, Ottawa, ON, Canada; Children's Hospital of Eastern Ontario Research Institute, University of Ottawa, Ottawa. Electronic address:
Purpose: Universal newborn hearing screening (UNHS) programs using audiometric techniques alone are limited in ability to detect non-congenital childhood permanent hearing loss (PHL). In 2019, Ontario launched universal newborn screening (NBS) for PHL risk factors: congenital cytomegalovirus (cCMV) and 22 common variants in GJB2 and SLC26A4. Here we describe our experience with genetic risk factor screening.
View Article and Find Full Text PDFCancer Med
January 2025
Division of Gastroenterology and Nephrology, Department of Multidisciplinary Internal Medicine, Faculty of Medicine, Tottori University, Yonago, Japan.
Background And Aim: In recent years, there has been a rise in cryptogenic hepatocellular carcinoma (c-HCC) cases in Japan, posing a detection challenge due to an unknown etiology. This study aims to enhance diagnostic strategies for c-HCC by analyzing its characteristics and exploring current opportunities for detection.
Methods: A retrospective study was conducted from April 2012 to March 2022, enrolling 372 newly diagnosed hepatocellular carcinoma (HCC) patients.
ACR Open Rheumatol
January 2025
Duke University and Duke Clinical Research Institute, Durham, North Carolina.
Objective: The objective of this study was to evaluate the preliminary effectiveness of an electronic pill bottle with automated reminders on hydroxychloroquine (HCQ) adherence in children with pediatric systemic lupus erythematosus (pSLE).
Methods: This was a self-controlled, open label, direct-to-family pilot trial. Children with pSLE treated with HCQ were recruited from the Childhood Arthritis and Rheumatology Research Alliance Registry.
Magn Reson Med
January 2025
F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA.
Purpose: We hypothesized that radiation-induced tubulointerstitial changes in the kidney can be assessed using MRI-based T relaxation time measurements.
Methods: We performed MRI, histology, and serum biochemistry in two mouse models of radiation nephropathy: one involving external beam radiotherapy and the other using internal irradiation with an α-particle-emitting actinium-225 radiolabeled antibody. We compared the mean T values of different renal compartments between control and external beam radiotherapy or α-particle-emitting actinium-225 radiolabeled antibody-treated groups and between the two radiation-treated groups using a Wilcoxon rank-sum test.
ACS Appl Mater Interfaces
January 2025
Beijing Key Laboratory of Construction-Tailorable Advanced Functional Materials and Green Applications Experimental Center of Advanced Materials, School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081, China.
Metal halide perovskites (MHPs) are promising materials for radiation detection. Compared with polycrystalline films, single crystals (SCs) have lower defect density, higher carrier mobility, and lifetime. However, the direct synthesis of MHP SCs for large-area flat panel imaging detectors remains challenging.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!