Purpose: Interfraction and intrafraction changes in amplitude of liver motion were assessed in patients with liver cancer treated with kV cone beam computed tomography (CBCT)-guided stereotactic body radiation therapy (SBRT).
Methods And Materials: A total of 314 CBCTs obtained with the patient in the treatment position immediately before and after each fraction, and 29 planning 4DCTs were evaluated in 29 patients undergoing six-fraction SBRT for unresectable liver cancer, with (n = 15) and without (n = 14) abdominal compression. Offline, the CBCTs were sorted into 10 bins, based on phase of respiration. Liver motion amplitude was measured using liver-to-liver alignment from the end-exhale and end-inhale CBCT and four-dimensional CT reconstructions. Inter- and intrafraction amplitude changes were measured from the difference between the pre-SBRT CBCTs relative to the planning four-dimensional CT, and from the pre-SBRT and post-SBRT CBCTs, respectively.
Results: Mean liver motion amplitude for all patients (range) was 1.8 (0.1-7.0), 8.0 (0.1-18.8), and 4.3 (0.1-12.1) mm in the mediolateral (ML), craniocaudal (CC), and anteroposterior (AP) directions, respectively. Mean absolute inter- and intrafraction liver motion amplitude changes were 1.0 (ML), 1.7 (CC), and 1.6 (AP) mm and 1.3 (ML), 1.6 (CC), and 1.9 (AP) mm, respectively. No significant correlations were found between intrafraction amplitude change and intrafraction time (range, 4:56-25:37 min:sec), and between inter- and intrafraction amplitude changes and liver motion amplitude. Intraobserver reproducibility (sigma, n = 29 fractions) was 1.3 (ML), 1.4 (CC), and 1.4 (AP) mm.
Conclusions: For the majority of liver SBRT patients, the change in liver motion amplitude was minimal over the treatment course and showed no apparent relationships with the magnitude of liver motion and intrafraction time.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijrobp.2009.09.008 | DOI Listing |
Sensors (Basel)
December 2024
Research Department of Imaging Physics and Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London WC2R 2LS, UK.
MR elastography is a non-invasive imaging technique that provides quantitative maps of tissue biomechanical properties, i.e., elasticity and viscosity.
View Article and Find Full Text PDFAntioxidants (Basel)
December 2024
Raydel Research Institute, Medical Innovation Complex, Daegu 41061, Republic of Korea.
The prolonged consumption of D-galactose (Gal) has been associated with severe damage in the liver and brain via exacerbation of oxidative stress, non-enzymatic glycation, and the aging process. The current study was initiated for a comparative assessment of beeswax alcohol (BWA, final 0.5% and 1.
View Article and Find Full Text PDFWhole-body PET imaging is often hindered by respiratory motion during acquisition, causing significant degradation in the quality of reconstructed activity images. An additional challenge in PET/CT imaging arises from the respiratory phase mismatch between CT-based attenuation correction and PET acquisition, leading to attenuation artifacts. To address these issues, we propose two new, purely data-driven methods for the joint estimation of activity, attenuation, and motion in respiratory self-gated TOF PET.
View Article and Find Full Text PDFMed Phys
January 2025
National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Background: Respiratory motion during radiotherapy (RT) may reduce the therapeutic effect and increase the dose received by organs at risk. This can be addressed by real-time tracking, where respiration motion prediction is currently required to compensate for system latency in RT systems. Notably, for the prediction of future images in image-guided adaptive RT systems, the use of deep learning has been considered.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Radiology, The First Affiliated Hospital of Guangxi Medical University, Nanning, China.
This study aimed to establish and validate a multiparameter prediction model for Ki67 expression in hepatocellular carcinoma (HCC) patients while also exploring its potential to predict the one-year recurrence risk. The clinical, pathological, and imaging data of 83 patients with HCC confirmed by postoperative pathology were analyzed, and the patients were randomly divided into a training set (n = 58) and a validation set (n = 25) at a ratio of 7:3. All patients underwent a magnetic resonance imaging (MRI) scan that included multi-b value diffusion-weighted scanning before surgery, and quantitative parameters were obtained via intravoxel incoherent motion (IVIM) and diffusion kurtosis (DKI) models.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!