Three experiments were conducted to evaluate the impact of centrifugation on cooled and frozen preservation of equine semen. A standard centrifugation protocol (600 x g for 10 min=CP1) was compared to four protocols with increasing g-force and decreased time period (600 x g, 1200 x g, 1800 x g and 2400 x g for 5 min for CP2, 3, 4, and 5, respectively) and to an uncentrifuged negative control. In experiment 1, the influence of the different CPs on sperm loss was evaluated by calculating the total number of sperm cells in 90% of the supernatant. Moreover, the effect on semen quality following centrifugation was assessed by monitoring several sperm parameters (membrane integrity using SYBR14-PI, acrosomal status using PSA-FITC, percentage total motility (TM), percentage progressive motility (PM) and beat cross frequency (BCF) obtained with computer assisted sperm analysis (CASA)) immediately after centrifugation and daily during chilled storage for 3 d. The use of CP1 resulted in a sperm loss of 22%. Increasing the centrifugation force to 1800 x g and 2400 x g for 5 min led to significantly lower sperm losses (7.4% and 2.1%, respectively; P<0.05). Compared to the uncentrifuged samples, centrifugation of semen resulted in a better sperm quality after chilled storage. There were minimal differences between the CPs although total motility was lower for CP2 than for the other treatments (P<0.005). In experiment 2, the centrifuged samples were cryopreserved using a standard freezing protocol and analyzed immediately upon thawing. Samples centrifuged according to CP2 resulted in a higher BCF (P<0.005), whereas CP3 and CP5 yielded a lower BCF (P<0.05) when compared to CP1. There were no post thaw differences between CP1 and CP4. In experiment 3, DNA integrity of the different samples was analyzed using TUNEL. Although DNA integrity decreased over time, CP had no impact. In conclusion, the loss of sperm cells in the supernatant after centrifugation can be substantially reduced by increasing the g-force up to 1800 x g or 2400 x g for a shorter period of time (5 min) compared to the standard protocol without apparent changes in semen quality, resulting in a considerable increase in the number of insemination doses per ejaculate.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.theriogenology.2010.01.022 | DOI Listing |
Animals (Basel)
November 2024
Department of Animal Pathology, Faculty of Veterinary Sciences, Universidad de Zaragoza, Miguel Servet 177, 50013 Zaragoza, Spain.
Currently, plastic is used being without any limitations. The livestock sector is no stranger to its use. For example, artificial insemination involves the use of different plastic materials, including semen straws and insemination catheters, which increase the levels of waste in our environment.
View Article and Find Full Text PDFJ Equine Vet Sci
December 2024
STgenetics Navasota Texas, USA.
The application of sex-sorted semen in horses has historically lagged the bovine industry due to differences in the reproductive physiology and grater variability in equine semen quality. Recent advancements, including SuperGen™ sorters and Ultraplus™ semen processing methods developed by STgenetics® (Navasota, Texas), have significantly improved the efficiency of the sex-sorting process and reduced the sperm damage previously reported. To facilitate the broader use sex-sorted semen in the equine industry, it is essential to address challenges such as shipping cooled semen to a central sorting facility, minimizing oxidative stress and DNA fragmentation, and developing effective methods for short-term cooling or long-term cryopreservation of the sex-sorted sperm.
View Article and Find Full Text PDFAnim Reprod
November 2024
Departamento de Reprodução Animal, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, São Paulo, SP, Brasil.
Intracytoplasmic Sperm Injection (ICSI) has increased usage in cases of stallion fertility issues, particularly for older stallions, those with reduced sperm numbers or quality, or stallions that have passed away, and only a limited amount of frozen semen is available. By manipulating the frozen semen through thawing, diluting, and refreezing or by cutting the straw under liquid nitrogen, the supply of semen for ICSI can be extended. While ICSI requires a minimal number of spermatozoa per procedure, it is important to consider sperm quality as a crucial factor affecting fertilization and embryo development.
View Article and Find Full Text PDFAnim Reprod Sci
January 2025
Department of Animal and Poultry Physiology, Faculty of Animal Science, Gorgan University of Agricultural Sciences and Natural Resources, Gorgan, Golestan, Iran. Electronic address:
Cryopreservation is a crucial method for the preservation of genetic materials. Nevertheless, this technique can have adverse effects due to cryo-oxidative damage. The primary objective of this study was to investigate the cryo-protective effects of niosomal nanocarriers loaded with artemisinin (NN-Art) on the functional attributes of equine spermatozoa.
View Article and Find Full Text PDFJ Equine Vet Sci
November 2024
Department of Animal Sciences, University of Florida, Gainesville, FL, USA. Electronic address: