Objective: Calculate error prevalence occurred in different medication-dispensing systems, the stages of occurrence, and contributing factors.

Methodology: Prospective observational study. The staging of the dispensing process were reviewed in five dispensing systems: Stock, Unitary-Dose dispensing systems (UDDS) without Computerized Prescription Order Entry (CPOE), CPOE-UDDS, Automated Dispensing Systems (ADS) without CPOE and CPOE-ADS. Dispensing errors were identified, together with the stages of occurrence of such errors and their contributing factors.

Results: 2,181 errors were detected among 54,169 opportunities of error. Error-rate: Stock, 10.7%; no-CPOE-UDDS, 3.7%, CPOE-UDDS, 2.2%, no-CPOE-ADS, 20.7%; CPOE-ADS, 2.9%. Most frequent stage when error occurs: Stock, preparation of order; no-CPOE-UDDS and CPOE-UDDS, filling of the unit dose cart; no-CPOE-ADS and CPOE-ADS, filling of the ADS. Most frequent error: Stock, no-CPOE-ADS and CPOE-ADS, omission; CPOE-UDDS, different amount of drug and no-CPOE-UDDS, extra medication. Contributing factor: Stock, CPOE-ADS and no-CPOE-ADS, stock out/supply problems; CPOE-UDDS, inexperienced personnel and deficient communication system between professionals; no-CPOE-UDDS, deficient communication system between professionals.

Conclusions: Applying new technologies to the dispensing process has increased its safety, particularly, implementation of CPOE has enabled to reduce dispensing errors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.farma.2009.12.003DOI Listing

Publication Analysis

Top Keywords

dispensing systems
12
stages occurrence
8
dispensing process
8
dispensing errors
8
no-cpoe-ads cpoe-ads
8
deficient communication
8
communication system
8
dispensing
7
stock
6
error
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!