A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Caustic injury: can CT grading system enable prediction of esophageal stricture? | LitMetric

Background: The aim of this study was to test the utility of our computed tomography (CT) grading system, compared with endoscopy, for association with the development of esophageal stricture in patients with caustic ingestion.

Methods: This retrospective case series involved 49 patients with caustic ingestion from 1998 to 2009. The degree of esophageal damage was graded using a scoring system based on the extent of esophageal wall edema and the damage in adjacent tissue as seen on thoracoabdominal CT scans. The presence of esophageal stricture was established by esophagography. Diagnostic performance was compared using receiver operating characteristic (ROC) analysis. Sensitivity and specificity were calculated for the grading system.

Results: The CT grading score results showed that grade III was the most common injury (20 cases, 40.8%), followed by grade IV (14 cases, 28.6%), grade II (9 cases, 18.4%), and grade I (6 cases, 12.2%). In addition, damage to the esophagus was significantly correlated with esophageal stricture when the extent of damage approached grades III and IV (p < 0.001). The CT grading system for esophageal stricture resulted in a slightly larger area under the receiver operating characteristic curve (0.90) compared with endoscopic grading system (0.79). The sensitivity and specificity of CT grading system were moderately higher than those of endoscopic grading system.

Conclusion: Assessment of the degree of esophageal damage using CT, a noninvasive modality, in patients who visit the emergency department following caustic ingestion should be useful in estimating the occurrence of complications including esophageal stricture.

Download full-text PDF

Source
http://dx.doi.org/10.3109/15563650903585929DOI Listing

Publication Analysis

Top Keywords

grading system
20
esophageal stricture
20
grade cases
12
esophageal
9
grading
8
patients caustic
8
caustic ingestion
8
degree esophageal
8
esophageal damage
8
receiver operating
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!